SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-187737"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-187737" > Four-dimensional fl...

Four-dimensional flow cardiac magnetic resonance assessment of left ventricular diastolic function

Ashkir, Zakariye (författare)
Univ Oxford, England
Myerson, Saul (författare)
Univ Oxford, England
Neubauer, Stefan (författare)
Univ Oxford, England
visa fler...
Carlhäll, Carljohan (författare)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
Ebbers, Tino (författare)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Raman, Betty (författare)
Univ Oxford, England
visa färre...
 (creator_code:org_t)
2022-07-22
2022
Engelska.
Ingår i: Frontiers in Cardiovascular Medicine. - : FRONTIERS MEDIA SA. - 2297-055X. ; 9
  • Forskningsöversikt (refereegranskat)
Abstract Ämnesord
Stäng  
  • Left ventricular diastolic dysfunction is a major cause of heart failure and carries a poor prognosis. Assessment of left ventricular diastolic function however remains challenging for both echocardiography and conventional phase contrast cardiac magnetic resonance. Amongst other limitations, both are restricted to measuring velocity in a single direction or plane, thereby compromising their ability to capture complex diastolic hemodynamics in health and disease. Time-resolved three-dimensional phase contrast cardiac magnetic resonance imaging with three-directional velocity encoding known as 4D flow CMR is an emerging technology which allows retrospective measurement of velocity and by extension flow at any point in the acquired 3D data volume. With 4D flow CMR, complex aspects of blood flow and ventricular function can be studied throughout the cardiac cycle. 4D flow CMR can facilitate the visualization of functional blood flow components and flow vortices as well as the quantification of novel hemodynamic and functional parameters such as kinetic energy, relative pressure, energy loss and vorticity. In this review, we examine key concepts and novel markers of diastolic function obtained by flow pattern analysis using 4D flow CMR. We consolidate the existing evidence base to highlight the strengths and limitations of 4D flow CMR techniques in the surveillance and diagnosis of left ventricular diastolic dysfunction.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

diastolic function; heart failure; 4D flow cardiac MR; kinetic energy; flow components; vortex

Publikations- och innehållstyp

ref (ämneskategori)
for (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy