SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-19422"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-19422" > Evaluation of a lit...

  • Antonovic, LauraLinköpings universitet,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet (författare)

Evaluation of a lithium formate EPR dosimetry system for dose measurements around Ir-192 brachytherapy sources

  • Artikel/kapitelEngelska2009

Förlag, utgivningsår, omfång ...

  • 2009-05-18
  • Wiley,2009
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-19422
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-19422URI
  • https://doi.org/10.1118/1.3110068DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Original Publication: Laura Antonovic, Håkan Gustafsson, Gudrun Alm Carlsson and Åsa Carlsson Tedgren, Evaluation of a lithium formate EPR dosimetry system for dose measurements around Ir-192 brachytherapy sources, 2009, MEDICAL PHYSICS, (36), 6, 2236-2247. http://dx.doi.org/10.1118/1.3110068 Copyright: American Institute of Physics http://www.aip.org/
  • A dosimetry system using lithium formate monohydrate (HCO2Li center dot H2O) as detector material and electron paramagnetic resonance (EPR) spectroscopy for readout has been used to measure absorbed dose distributions around clinical Ir-192 sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g/cm(3) were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam. Ir-192 irradiations were performed in a PMMA phantom using two different source models, the GammaMed Plus HDR and the microSelectron PDR-v1 model. Measured absorbed doses to water in the PMMA phantom were converted to the corresponding absorbed doses to water in water phantoms of dimensions used by the treatment planning systems (TPSs) using correction factors explicitly derived for this experiment. Experimentally determined absorbed doses agreed with the absorbed doses to water calculated by the TPS to within +/- 2.9%. Relative standard uncertainties in the experimentally determined absorbed doses were estimated to be within the range of 1.7%-1.3% depending on the radial distance from the source, the type of source (HDR or PDR), and the particular absorbed doses used. This work shows that a lithium formate dosimetry system is well suited for measurements of absorbed dose to water around clinical HDR and PDR Ir-192 sources. Being less energy dependent than the commonly used thermoluminescent lithium fluoride (LiF) dosimeters, lithium formate monohydrate dosimeters are well suited to measure absorbed doses in situations where the energy dependence cannot easily be accounted for such as in multiple-source irradiations to verify treatment plans. Their wide dynamic range and linear dose response over the dose interval of 0.2-1000 Gy make them suitable for measurements on sources of the strengths used in clinical applications. The dosimeter size needs, however, to be reduced for application to single-source dosimetry.

Ämnesord och genrebeteckningar

  • brachytherapy
  • dosimetry
  • organic compounds
  • paramagnetic resonance
  • phantoms
  • thermoluminescent dosimeters
  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Gustafsson, HåkanLinköpings universitet,Medicinsk radiofysik,Hälsouniversitetet(Swepub:liu)hakgu16 (författare)
  • Alm Carlsson, GudrunÖstergötlands Läns Landsting,Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen(Swepub:liu)gudal03 (författare)
  • Carlsson Tedgren, ÅsaÖstergötlands Läns Landsting,Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen(Swepub:liu)asaca90 (författare)
  • Linköpings universitetAvdelningen för radiologiska vetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:MEDICAL PHYSICS: Wiley36:6, s. 2236-22470094-2405

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy