SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-21238"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-21238" > Tissue viability im...

  • Henricson, JoakimLinköpings universitet,Institutionen för klinisk och experimentell medicin,Hälsouniversitetet (författare)

Tissue viability imaging : Microvascular response to vasoactive drugs induced by iontophoresis

  • Artikel/kapitelEngelska2009

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2009
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-21238
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-21238URI
  • https://doi.org/10.1016/j.mvr.2009.04.008DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Original Publication: Joakim Henricson, Anders Nilsson, Erik Tesselaar, Gert Nilsson and Folke Sjöberg, Tissue viability imaging: Microvascular response to vasoactive drugs induced by iontophoresis, 2009, Microvascular Research, (78), 2, 199-205. http://dx.doi.org/10.1016/j.mvr.2009.04.008 Copyright: Elsevier Science B.V., Amsterdam http://www.elsevier.com/
  • When one is studying the physiology of the cutaneous microcirculation there is a need for relevant non-invasive and versatile techniques. In this study we used a new optical device, the tissue viability imager (TiVi), to map changes in cutaneous microvascular concentrations of red blood cells during iontophoresis of vasoactive substances (noradrenaline (NA) and phenylephrine (Phe) for vasoconstriction and acetylcholine (ACh) and sodium nitroprusside (SNP) for vasodilatation). We aimed to present data both individually and pooled, using a four-variable logistic dose response model that is commonly used in similar in vitro vascular studies. The accuracy of the TiVi was also investigated by calculating the coefficient of variation and comparing it with similar tests previously done using laser Doppler imaging. Tests were also performed using the TiVi and LDPI simultaneously to further compare the two methods. Results showed that the TiVi is capable of quantifying vascular responses to iontophorised noradrenaline and phenylephrine without the need to increase background flow first. Fitting the TiVi data to the dose response model resulted in ED50-values with narrow confidence intervals and acceptable r2 values. Mean ED50-values for the TiVi did not differ significantly from similar values obtained using laser Doppler. Results further seem to suggest that when the blood perfusion increases during vasodilatation in skin the initial phase relies mainly on an increase in red blood cell concentration whereas the further perfusion increase is due to an increase in red blood cell velocity.

Ämnesord och genrebeteckningar

  • Cutaneous microcirculation; Iontophoresis; Laser Doppler; Tissue viability imager
  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Nilsson, AndersBerzelius Clinical Research Center AB (författare)
  • Tesselaar, ErikBerzelius Clinical Research Center AB (författare)
  • Nilsson, GertLinköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan(Swepub:liu)gerni17 (författare)
  • Sjöberg, FolkeÖstergötlands Läns Landsting,Linköpings universitet,Brännskadevård,Hälsouniversitetet,Hand- och plastikkirurgiska kliniken US(Swepub:liu)folsj94 (författare)
  • Linköpings universitetInstitutionen för klinisk och experimentell medicin (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Microvascular Research: Elsevier BV78:2, s. 199-2050026-2862

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy