SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-24544"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-24544" > Spectral signature ...

Spectral signature and heterodyne efficiency for different wavelengths in laser Doppler flowmetry

Arildsson, Mikael (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
Nilsson, Gert, 1947- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
Strömberg, Tomas, 1966- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
 (creator_code:org_t)
2002
2002
Engelska.
Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 40:1, s. 85-89
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Laser Doppler perfusion monitoring and imaging technologies generate time traces and two-dimensional flow maps of the microcirculation. With the goal of reaching different tissue depths, these technologies are equipped with lassers operating at different wavelengths λ. The fact that the average scattering angle, at a single scattering event, between a photon and a red blood cell increases with λ is compensated for by a 1/λ effect in the scattering vector, rendering the average frequency shift virtually independent of the choice of wavelength. Monte Carlo simulations showed that the corresponding spectral signature of the Doppler signals for λ=632.8nm and 780nm were close to identical. The theoretical predictions were verified by calculating the centre-of-gravity (COG) frequency of the laser Doppler power spectral density for the two wavelengths from forearm and finger skin, representing a low and high perfusion area, respectively (forearm COG=123 against 121Hz, finger COG=220 against 212 Hz). When the wavelength changes from 632.8nm to 780nm, the heterodyne efficiency of the detector and, thereby, the inherent system amplifcation increase. For tissues with identical microvascular flow conditions, the output signal therfore tends to increase in magnitude when shifting to longer wavelengths.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy