A new probe for ankle systolic pressure measurement using Photoplethysmography (PPG)

Jönsson, Björn, 1951- (författare)
Linköpings universitet,Kärlkirurgi,Hälsouniversitetet
Laurent, Claes, 1958- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
Skau, Tommy, 1949- (författare)
Linköpings universitet,Kärlkirurgi,Hälsouniversitetet
visa fler...
Lindberg, Lars-Göran, 1951- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
visa färre...
 (creator_code:org_t)
Springer Science and Business Media LLC, 2005
2005
Engelska.
Ingår i: Annals of Biomedical Engineering. - : Springer Science and Business Media LLC. - 0090-6964 .- 1573-9686. ; 33:2, s. 232-239
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • An automated method for ankle systolic pressure measurement, less operator dependent than the standard continuous wave (CW) Doppler technique, would imply an advantage both in patient measurements and in epidemiological studies. We present a new photoplethysmographic (PPG) probe that uses near-infrared light (880 nm) to detect pulsatory blood flow underneath the distal end of a standard pneumatic cuff. The probe is adapted to the anatomical conditions at the ankle, permitting recording of pressures in both ankle arteries separately. The validity of the equipment was tested with CW Doppler-derived systolic pressures and invasive blood pressure measurements for reference. In 20 healthy subjects, visual analysis of the PPG curves revealed a mean difference between CW Doppler and PPG measurements of –0.5 mmHg (SD 6.9). Corresponding results for the anterior and posterior tibial arteries separately were –1.8 mmHg (SD 6.2) and 0.9 mmHg (SD 7.3), respectively. A correct probe position was essential for the results. In direct recordings from the dorsalis pedis artery in 10 intensive care patients, PPG underestimated systolic pressure in the anterior tibial artery by 4.5 mmHg (SD 12.1). With further development, the PPG probe, integrated in the pneumatic cuff, may simplify measurements of ankle systolic pressures.

Nyckelord

near-infrared light
CW Doppler
leg
anterior tibial artery
posterior tibial artery
blood pressure determination
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy