Influence of tissue movement on laser Doppler perfusion imaging

Karlsson, Daniel M G, 1974- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,Biomedicinsk instrumentteknik
Larsson, Marcus, 1974- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
Strömberg, Tomas, 1966- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,Biomedicinsk instrumentteknik
visa fler...
Wårdell, Karin, 1959- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,Biomedicinsk instrumentteknik
visa färre...
 (creator_code:org_t)
SPIE, 2002
2002
Engelska.
Ingår i: <em></em><em>Proc. SPIE</em> 4624, Optical Diagnostics and Sensing of Biological Fluids and Glucose and Cholesterol Monitoring II, 106 (May 24, 2002), Vol. 4624. - : SPIE. ; , s. 106-114, s. 106-114
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The microvascular perfusion can be measured using laser Doppler blood flowmetry (LDF), a technique sensitive to the concentration of moving blood cells and their velocity. However, movements of the tissue itself can cause artifacts in the perfusion readings. In a clinical situation, these movement induced artifacts may arise from patient movements or from movements of internal organs e.g. the intestines or the beating heart. Therefore, we have studied how a well-controlled tissue movement affects the LDF signals during different flow conditions and for different surface structures. Tissue perfusion was recorded non-touch in one point using a laser Doppler perfusion imager. During the measurements the object was placed on a shaker that generated the movement (both horizontal and vertical). Measurements were carried out both on DELRIN® (polyacetal plastic) and the fingertip, for a wide range of velocities (0-3 cm/s). The influence of the microvascular perfusion was evaluated by occluding the brachial artery as well as blood emptying the finger and by using a flow model. The LDF signals were correlated to the movement. In vivo measurements showed that velocities above 0.8 cm/s gave a significant contribution to the perfusion signal. Corresponding velocities for the DELRIN® piece were higher (1.4 – 2.6 cm/s), and dependent on the surface structures and reflecting properties. By reducing the amount of specular reflection the movement influence was substantially lowered.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Karlsson, Daniel ...
Larsson, Marcus, ...
Strömberg, Tomas ...
Wårdell, Karin, ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
Artiklar i publikationen
Proceedings of S ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy