SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-43406"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-43406" > Difficulties for pr...

Difficulties for primary health care staff in interpreting bacterial findings on a device for simplified urinary culture

Palmqvist, Elisabeth (författare)
Clinical Microbiology Laboratory University Hospital Linköping
Aspevall, Olle (författare)
Clinical Microbiology Akademiska laboratorierna, Uppsala
Burman, Eva (författare)
EQUALIS AB Uppsala
visa fler...
Nordin, Gunnar (författare)
EQUALIS AB Uppsala
Svahn, Anita (författare)
EQUALIS AB Uppsala
Forsum, Urban, 1946- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Klinisk mikrobiologi
visa färre...
 (creator_code:org_t)
2009-07-08
2008
Engelska.
Ingår i: Scandinavian Journal of Clinical and Laboratory Investigation. - : Informa UK Limited. - 0036-5513 .- 1502-7686. ; 68:4, s. 312-316
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The reliability of interpretations of findings from dip-slide devices for culturing urine was investigated in a national Swedish external quality assessment (EQA) programme. Also investigated was the extent of improvement in the examination procedure achieved through personnel training programmes and information. According to Swedish national recommendations, dip-slide should only be used in primary health care (PHC) in cases of uncomplicated urinary tract infection (UTI) in females of childbearing age. The recommendations also define six possible outcomes of a dip-slide examination, outcomes that have formed the basis for the EQA programme since 2001. No improvement in ability to classify readings correctly into the six categories was noted for the period 2001 to 2006. Preparations containing 'mixed flora' presented participants with the greatest difficulty, with only 28% correct reports. The EQA programme, with educational components and voluntary participation, has not improved quality. The disappointing results might be a reflection of the limited effort and resources allocated by clinical microbiology laboratories for training and for sustaining proficiency in the evaluation of dip-slides. For these reasons, we cannot at present recommend the dip-slide technique for use in PHC settings. © 2008 Informa UK Ltd (Informa Healthcare, Taylor & Francis AS).

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy