Sökning: onr:"swepub:oai:DiVA.org:liu-48866" >
Time-frequency and ...
Time-frequency and complexity analyses for differentiation of physiologic murmurs from heart murmurs caused by aortic stenosis in boxers
-
- Hoglund, K. (författare)
- Höglund, K., Department of Anatomy and Physiology, Faculty of Veterinary Medicine and Animal Science, Swedish University of Agricultural Sciences, 750 07 Uppsala, Sweden
-
- Ahlström, Christer (författare)
- Linköpings universitet,Tekniska högskolan,Fysiologisk mätteknik
-
- Haggstrom, J. (författare)
- Häggström, J., Department of Clinical Sciences, Faculty of Veterinary Medicine and Animal Science, Swedish University of Agricultural Sciences, 750 07 Uppsala, Sweden
-
visa fler...
-
- Ask, Per, 1950- (författare)
- Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
-
- Hult, Peter (författare)
- Linköpings universitet,Tekniska högskolan,Fysiologisk mätteknik
-
- Kvart, C. (författare)
- Department of Anatomy and Physiology, Faculty of Veterinary Medicine and Animal Science, Swedish University of Agricultural Sciences, 750 07 Uppsala, Sweden
-
visa färre...
-
Höglund, K, Department of Anatomy and Physiology, Faculty of Veterinary Medicine and Animal Science, Swedish University of Agricultural Sciences, 750 07 Uppsala, Sweden Tekniska högskolan (creator_code:org_t)
- American Veterinary Medical Association (AVMA), 2007
- 2007
- Engelska.
-
Ingår i: American Journal of Veterinary Research. - : American Veterinary Medical Association (AVMA). - 0002-9645 .- 1943-5681. ; 68:9, s. 962-969
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.2...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective - To investigate whether time-frequency and complexity analyses of heart murmurs can be used to differentiate physiologic murmurs from murmurs caused by aortic stenosis (AS) in Boxers. Animals - 27 Boxers with murmurs. Procedures - Dogs were evaluated via auscultation and echocardiography. Analyses of time-frequency properties (TFPs, ie, maximal murmur frequency and duration of murmur frequency > 200 Hz) and correlation dimension (T2) of murmurs were performed on phonocardiographic sound data. Time-frequency property and T2 analyses of low-intensity murmurs in 16 dogs without AS were performed at 7 weeks and 12 months of age. Additionally, TFP and T2 analyses were performed on data obtained from 11 adult AS-affected dogs with murmurs. Results - In dogs with low-intensity murmurs, TFP or T2 values at 7 weeks and 12 months did not differ significantly. For differentiation of physiologic murmurs from murmurs caused by mild AS, duration of murmur frequency > 200 Hz was useful and the combination assessment of duration of frequency > 200 Hz and T2 of the murmur had a sensitivity of 94% and a specificity of 82%. Maximal murmur frequency did not differentiate dogs with AS from those without AS. Conclusions and Clinical Relevance - Results suggested that assessment of the duration of murmur frequency > 200 Hz can be used to distinguish physiologic heart murmurs from murmurs caused by mild AS in Boxers. Combination of this analysis with T2 analysis may be a useful complementary method for diagnostic assessment of cardiovascular function in dogs.
Nyckelord
- TECHNOLOGY
- TEKNIKVETENSKAP
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas