Non-invasive continuous estimation of blood flow changes in human patellar bone

Naslund, J. (författare)
Näslund, J., Department of Physiology and Pharmacology, Karolinska Institutet, 171 77 Stockholm, Sweden
Pettersson, Jonas (författare)
Linköpings universitet,Tekniska högskolan,Institutionen för medicinsk teknik
Lundeberg, T. (författare)
Rehabilitation Medicine University Clinic Stockholm, Danderyds Hospital, Stockholm, Sweden
visa fler...
Linnarsson, D. (författare)
Karolinska Institutet
Lindberg, Lars-Göran (författare)
Linköpings universitet,Tekniska högskolan,Fysiologisk mätteknik
visa färre...
Näslund, J, Department of Physiology and Pharmacology, Karolinska Institutet, 171 77 Stockholm, Sweden Tekniska högskolan (creator_code:org_t)
2006-06-03
2006
Engelska.
Ingår i: Medical and Biological Engineering and Computing. - : Springer Science and Business Media LLC. - 0140-0118 .- 1741-0444. ; 44:6, s. 501-509
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A photoplethysmographic (PPG) technique to assess blood flow in bone tissue has been developed and tested. The signal detected by the PPG consists of a constant-level (DC) component - which is related to the relative vascularization of the tissue - and a pulsatile (AC) component - which is synchronous with the pumping action of the heart. The PPG probe was applied on the skin over the patella. The probe uses near-infrared (804 nm) and green (560 nm) light sources and the AC component of the PPG signals of the two wavelengths was used to monitor pulsatile blood flow in the patellar bone and the overlying skin, respectively. Twenty healthy subjects were studied and arterial occlusion resulted in elimination of PPG signals at both wavelengths, whereas occlusion of skin blood flow by local surface pressure eliminated only the PPG signal at 560 nm. In a parallel study on a physical model with a rigid tube we showed that the AC component of the PPG signal originates from pulsations of blood flow in a rigid structure and not necessarily from volume pulsations. We conclude that pulsatile blood flow in the patellar bone can be assessed with the present PPG technique. © International Federation for Medical and Biological Engineering 2006.

Nyckelord

Bone
Near-infrared light
Perfusion
Photoplethysmography
Pulsatile
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy