Comparing k-ε Models On Predictions Of An Impinging Jet For Ventilation Of An Office Room

Chen, Huijuan (författare)
Högskolan i Gävle,Linköpings universitet,Energisystem,Tekniska högskolan,Energiteknik
Moshfegh, Bahram (författare)
Högskolan i Gävle,Linköpings universitet,Energisystem,Tekniska högskolan,Energiteknik
 (creator_code:org_t)
tapir academic press, 2011
2011
Engelska.
Ingår i: Proceedings of Roomvent 2011, 11<sup>th</sup> International Conference on Air Distribution in Rooms 19 - 22 June 2011 Torendheim, Norway. - : tapir academic press.
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The objective of this study is to compare the performance of different k-ε models, i.e. the Standard k-ε, the Renormalization Group (RNG) k-ε, and the Realizable k-ε, with a two-layer model for the prediction of the mean velocity field and the temperature pattern from a newly designed impinging jet supply device for ventilation of an office room. The numerical predictions are validated against the detailed experimental measurements. The experimental investigation was performed in a test room with the dimensions 4.2×3.6×2.5 m, as a mock-up of a single-person office. Detailed velocity and temperature field measurements including the comfort zone and the jet developing region along the floor were carried out. The in-house made single-sensor hot-wire probe and the thermocouple are measuring instruments used to investigate the mean velocity, turbulence intensity and temperature. The boundary conditions for Computational Fluid Dynamics (CFD) study are obtained from the same set-up measurement. The results mainly consist of the flow field presentation, i.e., the velocity and temperature profiles in the comfort zone and the jet developing region along the floor. The comparisons between the results from the three versions of the k-ε models and measurements show generally satisfactory agreement, and better consistency is observed at the free jet region and the wall jet region that farther from the impingement zone. Among the three tested turbulence models, RNG shows the best overall performance.

Nyckelord

CFD
Impinging jet ventilation
Turbulence model
Wall jet
Measurement

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Chen, Huijuan
Moshfegh, Bahram
Artiklar i publikationen
Roomvent 2011
Av lärosätet
Linköpings universitet
Högskolan i Gävle

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy