The 4th international comparison on EPR dosimetry with tooth enamel Part 1: Report on the results
-
- Fattibene, P (författare)
- Ist Super Sanita
-
- Wieser, A (författare)
- Helmholtz Zentrum Muenchen
-
- Adolfsson, Emelie, 1985- (författare)
- Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
-
visa fler...
-
- Benevides, L A (författare)
- USN
-
- Brai, M (författare)
- University of Palermo
-
- Callens, F (författare)
- University of Ghent
-
- Chumak, V (författare)
- Research Centre Radiat Medical AMS
-
- Ciesielski, B (författare)
- Medical University of Gdansk
-
- Della Monaca, S (författare)
- Ist Super Sanita
-
- Emerich, K (författare)
- Department Paediat Dentistry
-
- Gustafsson, Håkan, 1976- (författare)
- Linköpings universitet,Medicinsk radiologi,Hälsouniversitetet
-
- Hirai, Y (författare)
- Radiat Effects Research Fdn
-
- Hoshi, M (författare)
- Hiroshima University
-
- Israelsson, Axel (författare)
- Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
-
- Ivannikov, A (författare)
- Medical Radiol Research Centre
-
- Ivanov, D (författare)
- Institute Met Phys
-
- Kaminska, J (författare)
- Medical University of Gdansk
-
- Ke, Wu (författare)
- Beijing Institute Radiat Med
-
- Lund, Eva (författare)
- Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
-
- Marrale, M (författare)
- University of Palermo
-
- Martens, L (författare)
- University of Ghent
-
- Miyazawa, C (författare)
- Ohu University
-
- Nakamura, N (författare)
- Radiat Effects Research Fdn
-
- Panzer, W (författare)
- Helmholtz Zentrum Muenchen
-
- Pivovarov, S (författare)
- Institute Nucl Phys
-
- A Reyes, R (författare)
- Uniformed Serv University of Health Science
-
- Rodzi, M (författare)
- Hiroshima University
-
- Romanyukha, A A (författare)
- USN
-
- Rukhin, A (författare)
- Institute Nucl Phys
-
- Sholom, S (författare)
- Research Centre Radiat Medical AMS
-
- Skvortsov, V (författare)
- Medical Radiol Research Centre
-
- Stepanenko, V (författare)
- Medical Radiol Research Centre
-
- A Tarpan, M (författare)
- University of Ghent
-
- Thierens, H (författare)
- University of Ghent
-
- Toyoda, S (författare)
- Okayama University of Science
-
- Trompier, F (författare)
- Institute Radioprotect and Surete Nucl
-
- Verdi, E (författare)
- Helmholtz Zentrum Muenchen
-
- Zhumadilov, K (författare)
- Hiroshima University
-
visa färre...
-
(creator_code:org_t)
- Elsevier, 2011
- 2011
- Engelska.
-
Ingår i: Radiation Measurements. - : Elsevier. - 1350-4487 .- 1879-0925. ; 46:9, s. 765-771
- Relaterad länk:
-
https://biblio.ugent...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provided by the organizers. Nine molar teeth extracted following medical indication from German donors and collected between 1997 and 2007 were prepared and irradiated at the Helmholtz Zentrum Munchen. Five out of six samples were irradiated at 0.1, 0.2, 0.5, 1.0 and 1.5 Gy air kerma; and one unirradiated sample was kept as control. The doses delivered to the individual samples were unknown to the participants, who were asked to measure each sample nine times, and to report the EPR signal response, the mass of aliquots measured, and the parameters of EPR signal acquisition and signal evaluation. Critical dose and detection limit were calculated by the organizers on the basis of the calibration-curve parameters obtained at every laboratory. For calibration curves obtained by measuring every calibration sample three times, the mean value of the detection limit was 205 mGy, ranging from 56 to 649 mGy. The participants were also invited to provide the signal response and the nominal dose of their current dose calibration curve (wherever available), the critical dose and detection limit of which were also calculated by the organizers.
Nyckelord
- Electron paramagnetic resonance (EPR)
- Tooth enamel
- Detection limit
- Retrospective dosimetry
- MEDICINE
- MEDICIN
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Fattibene, P
-
Wieser, A
-
Adolfsson, Emeli ...
-
Benevides, L A
-
Brai, M
-
Callens, F
-
visa fler...
-
Chumak, V
-
Ciesielski, B
-
Della Monaca, S
-
Emerich, K
-
Gustafsson, Håka ...
-
Hirai, Y
-
Hoshi, M
-
Israelsson, Axel
-
Ivannikov, A
-
Ivanov, D
-
Kaminska, J
-
Ke, Wu
-
Lund, Eva
-
Marrale, M
-
Martens, L
-
Miyazawa, C
-
Nakamura, N
-
Panzer, W
-
Pivovarov, S
-
A Reyes, R
-
Rodzi, M
-
Romanyukha, A A
-
Rukhin, A
-
Sholom, S
-
Skvortsov, V
-
Stepanenko, V
-
A Tarpan, M
-
Thierens, H
-
Toyoda, S
-
Trompier, F
-
Verdi, E
-
Zhumadilov, K
-
visa färre...
- Artiklar i publikationen
-
Radiation Measur ...
- Av lärosätet
-
Linköpings universitet