2451 0a The 4th international comparison on EPR dosimetry with tooth enamel Part 1: Report on the results
264 1b Elsevier,c 2011
338 a print2 rdacarrier
500 a Funding Agencies|EC project SOUL|FIP6R-516478|
520 a This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provided by the organizers. Nine molar teeth extracted following medical indication from German donors and collected between 1997 and 2007 were prepared and irradiated at the Helmholtz Zentrum Munchen. Five out of six samples were irradiated at 0.1, 0.2, 0.5, 1.0 and 1.5 Gy air kerma; and one unirradiated sample was kept as control. The doses delivered to the individual samples were unknown to the participants, who were asked to measure each sample nine times, and to report the EPR signal response, the mass of aliquots measured, and the parameters of EPR signal acquisition and signal evaluation. Critical dose and detection limit were calculated by the organizers on the basis of the calibration-curve parameters obtained at every laboratory. For calibration curves obtained by measuring every calibration sample three times, the mean value of the detection limit was 205 mGy, ranging from 56 to 649 mGy. The participants were also invited to provide the signal response and the nominal dose of their current dose calibration curve (wherever available), the critical dose and detection limit of which were also calculated by the organizers.
653 a Electron paramagnetic resonance (EPR)
653 a Tooth enamel
653 a Detection limit
653 a Retrospective dosimetry
653 a MEDICINE
653 a MEDICIN
700a Wieser, Au Helmholtz Zentrum Muenchen4 aut
700a Adolfsson, Emelie,d 1985-u Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet4 aut0 (Swepub:liu)emead58
700a Benevides, L Au USN4 aut
700a Brai, Mu University of Palermo4 aut
700a Callens, Fu University of Ghent4 aut
700a Chumak, Vu Research Centre Radiat Medical AMS4 aut
700a Ciesielski, Bu Medical University of Gdansk4 aut
700a Della Monaca, Su Ist Super Sanita4 aut
700a Emerich, Ku Department Paediat Dentistry4 aut
700a Gustafsson, Håkan,d 1976-u Linköpings universitet,Medicinsk radiologi,Hälsouniversitetet4 aut0 (Swepub:liu)hakgu16
700a Hirai, Yu Radiat Effects Research Fdn4 aut
700a Hoshi, Mu Hiroshima University4 aut
700a Israelsson, Axelu Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet4 aut0 (Swepub:liu)axeis81
700a Ivannikov, Au Medical Radiol Research Centre4 aut
700a Ivanov, Du Institute Met Phys4 aut
700a Kaminska, Ju Medical University of Gdansk4 aut
700a Ke, Wuu Beijing Institute Radiat Med4 aut
700a Lund, Evau Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet4 aut0 (Swepub:liu)evalu78
700a Marrale, Mu University of Palermo4 aut
700a Martens, Lu University of Ghent4 aut
700a Miyazawa, Cu Ohu University4 aut
700a Nakamura, Nu Radiat Effects Research Fdn4 aut
700a Panzer, Wu Helmholtz Zentrum Muenchen4 aut
700a Pivovarov, Su Institute Nucl Phys4 aut
700a A Reyes, Ru Uniformed Serv University of Health Science4 aut
700a Rodzi, Mu Hiroshima University4 aut
700a Romanyukha, A Au USN4 aut
700a Rukhin, Au Institute Nucl Phys4 aut
700a Sholom, Su Research Centre Radiat Medical AMS4 aut
700a Skvortsov, Vu Medical Radiol Research Centre4 aut
700a Stepanenko, Vu Medical Radiol Research Centre4 aut
700a A Tarpan, Mu University of Ghent4 aut
700a Thierens, Hu University of Ghent4 aut
700a Toyoda, Su Okayama University of Science4 aut
700a Trompier, Fu Institute Radioprotect and Surete Nucl4 aut
700a Verdi, Eu Helmholtz Zentrum Muenchen4 aut
700a Zhumadilov, Ku Hiroshima University4 aut
710a Ist Super Sanitab Helmholtz Zentrum Muenchen4 org
773t Radiation Measurementsd : Elsevierg 46:9, s. 765-771q 46:9<765-771x 1350-4487x 1879-0925
856u https://biblio.ugent.be/publication/1224570/file/6751957.pdf
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-72666
8564 8u https://doi.org/10.1016/j.radmeas.2011.05.001

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy