Assessment of the accuracy of MRI wall shear stress estimation using numerical simulations
-
- Petersson, Sven (författare)
- Linköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet
-
- Dyverfeldt, Petter (författare)
- Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Centrum för medicinsk bildvetenskap och visualisering, CMIV
-
- Ebbers, Tino (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US,Centrum för medicinsk bildvetenskap och visualisering, CMIV
-
(creator_code:org_t)
- 2012-02-15
- 2012
- Engelska.
-
Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 36:1, s. 128-138
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
https://onlinelibrar...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose: To investigate the accuracy of wall shear stress (WSS) estimation using MRI. Specifically, to investigate the impact of different parameters and if MRI WSS estimates are monotonically related to actual WSS. Materials and Methods: The accuracy of WSS estimation using methods based on phase-contrast (PC) MRI velocity mapping, Fourier velocity encoding (FVE) and intravoxel velocity standard deviation mapping were studied using numerical simulations. The influence of spatial resolution, velocity encoding, wall segmentation, and voxel location were investigated over a range of WSS values. Results: WSS estimates were found to be sensitive to parameter settings in general and spatial resolution in particular. All methods underestimated WSS, except for the FVE-based method, which instead was extremely sensitive to voxel position relative to the wall. Methods using PC-based WSS estimation with wall segmentation showed to be accurate for low WSS, but were sensitive to segmentation errors. Conclusion: Even in the absence of noise and for relatively simple velocity profiles, MRI WSS estimates cannot always be assumed to be linearly or even monotonically related to actual WSS. High WSS values cannot be resolved and the estimates depend on parameter setting. Nevertheless, distinguishing areas of low and moderate WSS may be feasible.
Nyckelord
- wall shear stress; phase contrast magnetic resonance imaging; atherosclerosis; hemodynamics; Fourier velocity encoding; numerical simulations