SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-81058"
 

Search: onr:"swepub:oai:DiVA.org:liu-81058" > Factors influencing...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Ledent, ElisabethLinköpings universitet,Östergötlands Läns Landsting,Transfusionsmedicin och klinisk immunologi,Hälsouniversitetet (author)

Factors influencing white cell removal from red cell concentrates by filtration

  • Article/chapterEnglish1996

Publisher, publication year, extent ...

  • Wiley,1996
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:liu-81058
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-81058URI
  • https://doi.org/10.1046/j.1537-2995.1996.36896374375.xDOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • BACKGROUND: The preparation of blood components by hard centrifugation results in red cell concentrates with a small amount of plasma. The influence of various plasma factors, temperature, and storage time on white cell reduction by filtration was studied. STUDYDESIGN AND METHODS: Red cell concentrates were suspended in 100 mL of saline- adenine-glucose-mannitol (SAGMAN) solution or in SAGMAN solution in which 5 or 10 mL had been replaced with an equal amount of fresh plasma, albumin (4%), or heat-inactivated plasma. After overnight storage at 4 degrees C, filtration at a slow flow rate (2 hours) was performed. The effect of temperature was studied by filtration at 4 degrees C and 37 degrees C. To study the influence of storage time, red cell concentrates were stored for 4 to 8 hours or 14 to 20 hours at 4 degrees C and filtered through another model of filter. The number of white cells was counted microscopically or by flow cytometry.RESULTS: When 5 or 10 mL of plasma was added, a significantly smaller number of white cells were found after filtration than were found in the SAGMAN control (the median difference between pairs: 23.6 × 10(6) for 5 mL [p = 0.006] and 14.9 × 10(6) for 10 mL [p = 0.003]). The number of white cells was significantly higher with 10 mL of albumin than with 10 mL of plasma (difference, 15.0 × 10(6); p = 0.006). When heat-inactivated plasma was used, the number of white cells was significantly lower than when fresh plasma was used (difference, 0.3 × 10(6); p = 0.009). Filtration at 37 degrees C resulted in a 64-percent reduction in white cells and that at 4 degrees C led to a 99.7-percent reduction (p = 0.006). When the second filter was used, a slight but significantly lower number of white cells was found in the red cell concentrate stored for 14 to 20 hours than in that stored for 4 to 8 hours (difference, 0.03 × 10(6); p < 0.001).CONCLUSION: The amount of plasma in the red cell concentrate and the storage time and temperature are important factors in the outcome of white cell reduction by filtration. The effect of plasma does not seem to be due to a general influence of protein or to the activity of complement or fibrinogen.

Subject headings and genre

  • MEDICINE
  • MEDICIN

Added entries (persons, corporate bodies, meetings, titles ...)

  • Berlin, GöstaLinköpings universitet,Östergötlands Läns Landsting,Transfusionsmedicin och klinisk immunologi,Hälsouniversitetet(Swepub:liu)gosbe95 (author)
  • Östergötlands Läns LandstingTransfusionsmedicin och klinisk immunologi (creator_code:org_t)

Related titles

  • In:Transfusion: Wiley36:8, s. 714-7180041-11321537-2995

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Ledent, Elisabet ...
Berlin, Gösta
Articles in the publication
Transfusion
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view