SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-86654"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-86654" > Indirect Determinat...

Indirect Determination of Mercury Ion by Inhibition of a Glucose Biosensor Based on ZnO Nanorods

Chey, Chan Oeurn (författare)
Linköpings universitet,Institutionen för teknik och naturvetenskap,Tekniska högskolan
Ibupoto, Zafar Hussain (författare)
Linköpings universitet,Institutionen för teknik och naturvetenskap,Tekniska högskolan
Khun, Kimleang (författare)
Linköpings universitet,Institutionen för teknik och naturvetenskap,Tekniska högskolan
visa fler...
Nur, Omer (författare)
Linköpings universitet,Fysik och elektroteknik,Tekniska högskolan
Willander, Magnus (författare)
Linköpings universitet,Fysik och elektroteknik,Tekniska högskolan
visa färre...
 (creator_code:org_t)
2012-11-06
2012
Engelska.
Ingår i: Sensors. - : MDPI. - 1424-8220. ; 12:11, s. 15063-15077
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A potentiometric glucose biosensor based on immobilization of glucose oxidase (GOD) on ZnO nanorods (ZnO-NRs) has been developed for the indirect determination of environmental mercury ions. The ZnO-NRs were grown on a gold coated glass substrate by using the low temperature aqueous chemical growth (ACG) approach. Glucose oxidase in conjunction with a chitosan membrane and a glutaraldehyde (GA) were immobilized on the surface of the ZnO-NRs using a simple physical adsorption method and then used as a potentiometric working electrode. The potential response of the biosensor between the working electrode and an Ag/AgCl reference electrode was measured in a 1mM phosphate buffer solution (PBS). The detection limit of the mercury ion sensor was found to be 0.5 nM. The experimental results provide two linear ranges of the inhibition from 0.5 x 10(-6) mM to 0.5 x 10(-4) mM, and from 0.5 x 10(-4) mM to 20 mM of mercury ion for fixed 1 mM of glucose concentration in the solution. The linear range of the inhibition from 10(-3) mM to 6 mM of mercury ion was also acquired for a fixed 10 mM of glucose concentration. The working electrode can be reactivated by more than 70% after inhibition by simply dipping the used electrode in a 10 mM PBS solution for 7 min. The electrodes retained their original enzyme activity by about 90% for more than three weeks. The response to mercury ions was highly sensitive, selective, stable, reproducible, and interference resistant, and exhibits a fast response time. The developed glucose biosensor has a great potential for detection of mercury with several advantages such as being inexpensive, requiring minimum hardware and being suitable for unskilled users.

Nyckelord

potentiometric inhibition biosensor
mercury
glucose oxidase
ZnO nanorods
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng