SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:lnu-61277"
 

Sökning: onr:"swepub:oai:DiVA.org:lnu-61277" > Peripheral resoluti...

Peripheral resolution and contrast sensitivity : Effects of stimulus drift

Venkataraman, Abinaya Priya (författare)
KTH Royal Institute of Technology
Lewis, Peter (författare)
Linnéuniversitetet,Institutionen för medicin och optometri (MEO)
Unsbo, Peter (författare)
KTH,Biomedicinsk fysik och röntgenfysik,KTH Royal Institute of Technology
visa fler...
Lundström, Linda (författare)
KTH,Biomedicinsk fysik och röntgenfysik,KTH Royal Institute of Technology
visa färre...
 (creator_code:org_t)
Pergamon Press, 2017
2017
Engelska.
Ingår i: Vision Research. - : Pergamon Press. - 0042-6989 .- 1878-5646. ; 133, s. 145-149
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Optimal temporal modulation of the stimulus can improve foveal contrast sensitivity. This studyevaluates the characteristics oftheperipheral spatiotemporal contrast sensitivity function in normal-sighted subjects.The purpose is to identify a temporal modulation that can potentially improve the remaining peripheral visual function in subjects with central visual field loss. High contrast resolution cut-off for grating stimuli with four temporal frequencies (0, 5, 10 and 15 Hz drift) was first evaluated in the 10° nasal visual field.Resolution contrast sensitivity for all temporal frequencies was then measured at four spatial frequencies between 0.5 cycles per degree (cpd) and the measured stationary cut-off. All measurements were performed with eccentric optical correction. Similar to foveal vision, peripheral contrast sensitivity is highest for a combination of low spatial frequency and 5 to 10 Hz drift. At higher spatial frequencies, there was a decrease in contrast sensitivity with 15 Hz drift.Despitethis decrease, the resolution cut-off did not vary largely between the different temporal frequencies tested. ​ Additional measurements of contrast sensitivity at 0.5 cpd and resolution cut-off for stationary (0 Hz) and 7.5 Hz stimuli performed at 10, 15, 20 and 25° in the nasal visual field also showed the same characteristics across eccentricities.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Annan medicin och hälsovetenskap -- Övrig annan medicin och hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Other Medical and Health Sciences -- Other Medical and Health Sciences not elsewhere specified (hsv//eng)
NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

Contrast sensitivity
Drifting gratings
Peripheral vision
Spatial frequency
Temporal frequency
Optometry
Optometri

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy