SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:lnu-93089"
 

Sökning: onr:"swepub:oai:DiVA.org:lnu-93089" > Identification of t...

Identification of the running status of membrane walls in an opposed fired model boiler under varying heating loads

Fu, Jiapeng (författare)
Shandong University, China
Liu, Zhuhan (författare)
Xi'an Jiaotong University, China
Wei, Lin (författare)
Xi'an Jiaotong University, China
visa fler...
Lin, Leteng, 1980- (författare)
Linnéuniversitetet,Institutionen för byggd miljö och energiteknik (BET),Bioenergy
Li, Na (författare)
Xi'an Jiaotong University, China
Zhou, Qulan (författare)
Xi'an Jiaotong University, China
Ma, Chunyuan (författare)
Shandong University, China
visa färre...
 (creator_code:org_t)
Elsevier, 2020
2020
Engelska.
Ingår i: Applied Thermal Engineering. - : Elsevier. - 1359-4311 .- 1873-5606. ; 173, s. 1-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To understand the running status of membrane walls in an opposite firing boiler, a scale-down model furnace was established, and the temperature, heat flux, strain and stress distributions are investigated under four heating loads. Results show that the average membrane wall temperature and heat flux present a continuous increase from 42 oC and 16 W/m2 to 96 oC and 50 W/m2, respectively, with the heating load increase from 25% to full load. The average strain and stress also rise from 88.7 µm and 0.094 MPa to 152.5 µm and 0.148 MPa when the heating load increases from 25% to 50%, but then they keep stable when further increasing the heating load. General distribution patterns of each tested parameter are found relatively similar under varying heating loads. High strain and stress distributions are always detected at the middle left zone of side walls and the middle of the rear wall, where wall temperatures are measured high. External fixed constraints and high-temperature thermal strain is found jointly affecting the strain and stress distribution of the membrane wall. A simplified mechanism of how the strain and stress on boiler membrane walls evolve is proposed after comprehensive discussion of the measurement results.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik -- Bioenergi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology -- Bioenergy (hsv//eng)

Nyckelord

Opposed fired boiler
Membrane walls
Heat flux
Strain and stress
Fixed constraint
Bioenergiteknik/Energi- och Miljöteknik
Bioenergy Technology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy