SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:ltu-14505"
 

Sökning: onr:"swepub:oai:DiVA.org:ltu-14505" > Laboratory study of...

Laboratory study of infiltration into two frozen engineered (sandy) soils recommended for bioretention

Moghadas, Shahab (författare)
Luleå tekniska universitet,Arkitektur och vatten
Perttu, Anna-Maria (författare)
Luleå tekniska universitet,Arkitektur och vatten
Viklander, Peter (författare)
Luleå tekniska universitet,Geoteknologi
visa fler...
Marsalek, Jiri (författare)
Luleå tekniska universitet,Arkitektur och vatten
Viklander, Maria (författare)
Luleå tekniska universitet,Arkitektur och vatten
visa färre...
 (creator_code:org_t)
2015-11-21
2016
Engelska.
Ingår i: Hydrological Processes. - : Wiley. - 0885-6087 .- 1099-1085. ; 30:8, s. 1251-1264
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Infiltration of water into two frozen engineered soils of different gradation was studied in laboratory soil columns 1.2 m long and 0.1 m in diameter. Prior to testing, the soil moisture was adjusted to two levels, described by the gravimetric water content of 5 or 10%, soils were compacted to about 80-90% of the maximum dry density, and refrigerated to temperatures ranging from −8 to −2 °C. Water with temperatures 8-9 °C was thereafter fed on the top of columns at a constant head and the times of water break through the column and reaching a steady percolation rate, as well as the percolation rate, were recorded. The soil water content was a critical factor affecting the thawing process; during freezing, soil moisture was converted into ice, which blocked pores, and its melting required high amounts of energy supplied by infiltrating water. Hence, the thawing of soils with higher initial water content was much slower than in lower moisture soils, and water breakthrough and the attainment of steady percolation required much longer times in higher moisture soils. Heat transfer between infiltrating water, soil ice and frozen soil particles was well described by the energy budget equations, which constitute a parsimonious model of the observed processes. The finer grained soil and more compacted soil columns exhibited reduced porosity and required longer times for soil thawing. Practical implications of study results for design of bioretention facilities (BFs) in cold climate include the use of coarse engineered soils and fitting BFs with a drain facilitating soil drainage before the onset of freezing weather. This article is protected by copyright. All rights reserved.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Vattenteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Water Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Geoteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Geotechnical Engineering (hsv//eng)

Nyckelord

VA-teknik
Urban Water Engineering
Soil Mechanics
Geoteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy