Sökning: onr:"swepub:oai:DiVA.org:ltu-96376" >
Multilayer Arrays f...
Multilayer Arrays for Neurotechnology Applications (MANTA): Chronically Stable Thin-Film Intracortical Implants
-
- Böhler, Christian (författare)
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany; BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany,Albert-Ludwigs-Universität Freiburg,University of Freiburg
-
- Vomero, Maria (författare)
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany; BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany,Albert-Ludwigs-Universität Freiburg,University of Freiburg
-
- Soula, Marisol (författare)
- Neuroscience Institute, Langone Medical Center, New York University, New York, 10016, USA,NYU Langone Health
-
visa fler...
-
- Vöröslakos, Mihály (författare)
- Neuroscience Institute, Langone Medical Center, New York University, New York, 10016, USA,NYU Langone Health
-
- Porto Cruz, Maria (författare)
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany; BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany,Albert-Ludwigs-Universität Freiburg,University of Freiburg
-
- Liljemalm, Rickard (författare)
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany,Albert-Ludwigs-Universität Freiburg,University of Freiburg
-
- Buzsaki, György (författare)
- Neuroscience Institute, Langone Medical Center, New York University, New York, 10016, USA; Department of Physiology and Neuroscience, Langone Medical Center, New York University, New York, 10016, USA; Department of Neurology, Langone Medical Center, New York University, New York, 10016, USA,NYU Langone Health
-
- Stieglitz, Thomas (författare)
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany; BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany; Bernstein Center Freiburg, University of Freiburg, 79110, Freiburg, Germany,Albert-Ludwigs-Universität Freiburg,University of Freiburg
-
- Asplund, Maria (författare)
- Luleå tekniska universitet,Omvårdnad och medicinsk teknik,Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany; BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany; Department of Microtechnology and Nanoscience, Chalmers University of Technology, Gothenburg, SE-41296, Sweden; Freiburg Institute for Advanced Studies (FRIAS), University of Freiburg, 79110, Freiburg, Germany,Albert-Ludwigs-Universität Freiburg,University of Freiburg,Luleå tekniska universitet (LTU),Luleå University of Technology (LTU),Chalmers tekniska högskola,Chalmers University of Technology
-
visa färre...
-
(creator_code:org_t)
- 2023-03-19
- 2023
- Engelska.
-
Ingår i: Advanced Science. - : John Wiley & Sons. - 2198-3844. ; 10:14
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://ltu.diva-por... (primary) (Raw object)
-
https://research.cha... (primary) (free)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://research.cha...
-
visa färre...
Abstract
Ämnesord
Stäng
- Flexible implantable neurointerfaces show great promise in addressing one of the major challenges of implantable neurotechnology, namely the loss of signal connected to unfavorable probe tissue interaction. The authors here show how multilayer polyimide probes allow high-density intracortical recordings to be combined with a reliable long-term stable tissue interface, thereby progressing toward chronic stability of implantable neurotechnology. The probes could record 10–60 single units over 5 months with a consistent peak-to-peak voltage at dimensions that ensure robust handling and insulation longevity. Probes that remain in intimate contact with the signaling tissue over months to years are a game changer for neuroscience and, importantly, open up for broader clinical translation of systems relying on neurotechnology to interface the human brain.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Neurovetenskaper (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Neurosciences (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Annan medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Other Medical Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Industriell bioteknik -- Medicinsk bioteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Industrial Biotechnology -- Medical Biotechnology (hsv//eng)
Nyckelord
- bioelectronics
- chronic recordings
- conducting polymers
- flexible probes
- neurotechnology
- tissue-device interfaces
- Medical Engineering
- Medicinsk teknik
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas