Accuracy of surgical guides from 2 different desktop 3D printers for computed tomography-guided surgery

Gjelvold, Björn (författare)
Malmö universitet,Odontologiska fakulteten (OD),Clinic of Prosthodontics, Centre of Dental Specialist Care, Lund, Sweden
Mahmood, Deyar Jallal Hadi (författare)
Malmö universitet,Odontologiska fakulteten (OD)
Wennerberg, Ann (författare)
Department of Prosthodontics, Institute of Odontology, Sahlgrenska Academy University of Gothenburg, Gothenburg, Sweden
 (creator_code:org_t)
Elsevier, 2019
2019
Engelska.
Ingår i: The Journal of prosthetic dentistry (Print). - : Elsevier. - 0022-3913 .- 1097-6841. ; 121:3, s. 498-503
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • STATEMENT OF PROBLEM: Different factors influence the degree of deviation in dental implant position after computed tomography-guided surgery. The surgical guide-manufacturing process with desktop 3D printers is such a factor, but its accuracy has not been fully evaluated.PURPOSE: The purpose of this in vitro study was to evaluate the deviation in final dental implant position after the use of surgical guides fabricated from 2 different desktop 3D printers using a digital workflow.MATERIAL AND METHODS: Twenty 3D-printed resin models were prepared with missing maxillary premolar. After preoperative planning, 10 surgical guides were produced with a stereolithography printer and 10 with a digital light-processing (DLP) printer. A guided surgery was performed; 20 dental implants (3.8×12 mm) were installed, and a digital scan of the dental implants was made. Deviations between the planned and final position of the dental implants were evaluated for both the groups.RESULTS: A statistically significant difference between stereolithography and DLP were found for deviation at entry point (P=.023) and the vertical implant position (P=.009). Overall lower deviations were found for the guides from the DLP printer, with the exception of deviation in horizontal implant position.CONCLUSIONS: The tested desktop 3D printers were able to produce surgical guides with similar deviations with regard to the final dental implant position, but the DLP printer proved more accurate concerning deviations at entry point and vertical implant position.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gjelvold, Björn
Mahmood, Deyar J ...
Wennerberg, Ann
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
The Journal of p ...
Av lärosätet
Malmö universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy