Sökning: onr:"swepub:oai:DiVA.org:mau-22020" >
Validity of compute...
Validity of computed tomography in diagnosing midfacial fractures.
-
- de Carvalho, M F (författare)
- Federal University of Juiz de Fora, Juiz de Fora, Brazil
-
- Vieira, J N M (författare)
- Federal University of Minas Gerais, Belo Horizonte, Brazil
-
- Figueiredo, R (författare)
- Federal University of Minas Gerais, Belo Horizonte, Brazil
-
visa fler...
-
- Reher, P (författare)
- School of Dentistry and Oral Health, Griffith University, Gold Coast, Australia
-
- Chrcanovic, Bruno Ramos, DDS, MSc, PhD (författare)
- Malmö universitet,Odontologiska fakulteten (OD)
-
- das Graças Afonso Miranda Chaves, M (författare)
- Federal University of Juiz de Fora, Juiz de Fora, Brazil
-
visa färre...
-
(creator_code:org_t)
- Elsevier, 2021
- 2021
- Engelska.
-
Ingår i: International Journal of Oral and Maxillofacial Surgery. - : Elsevier. - 0901-5027 .- 1399-0020. ; 50:4, s. 471-476
- Relaterad länk:
-
https://research-rep...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The aim of this study was to evaluate the sensitivity, accuracy, and reliability of two-dimensional computed tomography (2D-CT) scans (axial, coronal, sagittal planes) and three-dimensional computed tomography (3D-CT) reconstructions in diagnosing midfacial fractures in relation to actual fractures identified clinically and during surgery (gold standard). The imaging diagnosis was performed by a radiologist and an oral and maxillofacial surgeon. Sixty-two patients with a total of 429 midfacial fractures were included. Frontal sinus and nose fractures were easily diagnosed. For the three CT planes, there was a statistically significant difference between the CT examination and the gold standard for five to seven of the nine bones evaluated, while for 3D-CT, a difference was observed only for fractures of the orbital floor. The inter-observer agreement between the oral and maxillofacial surgeon and the radiologist was 75.5%. In conclusion, in this study 3D-CT reconstructions showed significantly the best sensitivity, accuracy, and reliability for the diagnosis of midfacial fractures. The sagittal reconstructions were the least diagnostic of the 2D-CT images. For areas where the parameters studied showed less agreement and hence a more difficult diagnosis, we recommend a combination of 3D and 2D-CT images to improve diagnostic accuracy.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Nyckelord
- Computed tomography
- Diagnosis
- Facial trauma
- Midfacial fractures
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas