  • Fernandes, Cláudio PinheiroMalmö högskola,Odontologiska fakulteten (OD) (författare)

A Novel Sensor for Bite Force Determinations

  • Artikel/kapitelEngelska2003

Förlag, utgivningsår, omfång ...

  • 2003
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:mau-6732
  • https://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-6732URI
  • https://doi.org/10.1016/S0109-5641(02)00020-9DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:vet swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • OBJECTIVES: The clinical usefulness, accuracy and precision of a novel bite force sensor based on force sensing resistors were tested in six subjects wearing maxillary removable partial dentures retained by conical crowns. METHODS: The surfaces of the sensor were manufactured in a silicone material that had mechanical properties similar to those of tough foodstuffs. In two separate series of standardized bite force tests, submaximum force levels were recorded with the sensor and with a strain gaged bite fork. Subjects were assisted in the loading tests with visual feedback instrumentation. Reliability estimates for the bite force sensor were calculated in order to show their reproducibility. Strain gages attached to the prostheses were used to determine the pattern of force distribution during loading tests. The bite force results obtained with the new bite force sensor and with the bite fork were analyzed with ANOVA and Scheffes tests. The strain patterns registered with strain gages were analyzed with F-test. RE-SULTS: The bite force sensor and the bite fork transducer showed no statistically significant differences in respect of intra-individual bite force levels (range 50-300N). The bite forces registered with the new sensor were dependent on the loading position (p<0.05), sex (p<0.05) and test subject (p<0.05). The reliability of the new sensor for sub-maximum bite forces was calculated to be 93%. Strain gage results showed that the new sensor generated strain patterns of less variance (p<0.05) than the bite fork and therefore allowed for higher precision during biting tests. SIGNIFICANCE: The presented instrument has such clinical merits, as to favor its use in experimental clinical studies on the biomechanics of prosthetic appliances.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Glantz, Per OlofMalmö högskola,Odontologiska fakulteten (OD)(Swepub:mau)odpogl (författare)
  • Svensson, Stig AMalmö högskola,Odontologiska fakulteten (OD) (författare)
  • Bergmark, A (författare)
  • Malmö högskolaOdontologiska fakulteten (OD) (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Dental Materials19:2, s. 118-1260109-56411879-0097

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Fernandes, Cláud ...
Glantz, Per Olof
Svensson, Stig A
Bergmark, A
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Dental Materials
Av lärosätet
Malmö universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy