Sökning: onr:"swepub:oai:DiVA.org:mau-67795" >
Cellular responses ...
Cellular responses to cobalt-chrome and CP titanium : an in vitro comparison of frameworks for implant-retained oral prostheses
-
- Hjalmarsson, Lars (författare)
- Malar Hosp, Specialist Prosthet Clin, Publ Dent Hlth Serv, SE-63188 Eskilstuna, Sweden,The Mälar Hospital, Eskilstuna, Sweden
-
- Smedberg, Jan-Ivan (författare)
- Malmö högskola,Odontologiska fakulteten (OD),St Erik Hosp, Specialist Prosthet Clin, Publ Dent Hlth Serv, Stockholm, Sweden
-
- Aronsson, Gunilla (författare)
- Univ Gothenburg, Dept Prosthet Dent Dent Mat Sci, Inst Odontol, Sahlgrenska Acad, Gothenburg, Sweden
-
visa fler...
-
- Wennerberg, Ann (författare)
- Malmö högskola,Odontologiska fakulteten (OD),Univ Gothenburg, Dept Biomat Handicap Res, Sahlgrenska Acad, Gothenburg, Sweden.
-
visa färre...
-
(creator_code:org_t)
- Swedish Dental Association, 2011
- 2011
- Engelska.
-
Ingår i: Swedish Dental Journal. - : Swedish Dental Association. - 0347-9994. ; 35:4, s. 177-186
- Relaterad länk:
-
https://mau.diva-por... (primary) (Raw object)
-
visa fler...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- The responses of cell types in pen-implant tissues to cobalt-chrome and titanium were studied in vitro. Cylinders were made from both a cobalt-chrome alloy and commercially pure titanium (length 6 mm, diameter 79 mm). Plastic tubes were placed over the cylinders to create cell culture wells, in which human epithelial cells or mouse fibroblasts were cultivated. Cell viability was studied using the Alamar Blue (TM) method. The surface structure of two samples of each material was analyzed with optical interferometry. The morphology of cells grown on cylinders of each material was studied with scanning electronic microscopy. Epithelial cells and fibroblasts in the titanium group were more viable than those in the cobalt-chrome group (p = 0.001 and p = 0.000, respectively). The titanium surfaces had a greater height deviation (S-a, p = 0.027) but were less dense (S-ds, p = 0.044) than the cobalt-chrome group. The scanning electronic microscopy revealed no major deviations from normal cell morphology. Within the limitations of the present study, the findings indicate that epithelial cells as well as fibroblasts have a stronger negative response to cobalt-chrome alloy than to titanium. We suggest that these differences can be explained only by the material per se and not by the minor differences in surface structure. Further and clinical studies are needed to confirm the significance of these findings.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Nyckelord
- Viability epithelial cells fibroblasts
- cobalt-chrome
- CP titanium
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas