Sökning: onr:"swepub:oai:DiVA.org:mdh-27226" >
Correlations in dif...
Correlations in different scales of metro carriage fire tests
-
- Li, Ying Zhen (författare)
- RISE,SP Fire Research,SP Fire Research, Sweden
-
- Ingason, Haukur (författare)
- RISE,SP Fire Research,SP – Sveriges Tekniska Forskningsinstitut / Brandteknik, skydd (BRs ),SP Fire Research, Sweden
-
- Lönnermark, Anders, 1968- (författare)
- RISE,Mälardalens högskola,Framtidens energi,SP Fire Research, Sweden,MERO,SP Brandteknik,SP – Sveriges Tekniska Forskningsinstitut / Brandteknik, skydd (BRs )
-
(creator_code:org_t)
- ISBN 9789187017971
- Borås : SP Technical Research Institute of Sweden, 2013
- Engelska.
-
Serie: SP Report ; 2013:13
-
Serie: SP Rapport, 0284-5172 ; 2013:13
-
Ingår i: Brandposten. - Borås : SP Technical Research Institute of Sweden. ; :48, s. 28-29
- Relaterad länk:
-
https://ri.diva-port... (primary) (Raw object)
-
visa fler...
-
http://www-v2.sp.se/...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- An analysis of four series of metro carriage fire tests in different scales was carried out. These metro carriage fire tests including 1:10 model scale tests, 1:3 model scale tests, 1/3 carriage section carriage tests and full scale tunnel tests. The correlation between different scales of carriage fire tests is carefully investigated. The mechanism of fire development is very similar in different scales of tests involving fully developed. A critical fire spread is identified as the key parameter to a fully developed carriage fire and is related to a minimum heat release rate. After the critical fire spread, the fire travels along the carriage at an approximately constant speed. The maximum heat release rate obtained for a fully developed fire is dependent on the ventilation conditions and also the type and configuration of the fuels, and a simple equation has been proposed to estimate the maximum heat release rate. Good agreement has also been found between different scales of maximum gas temperature, gas concentration and extinction coefficient. The heat fluxes from the flames could be slightly overestimated in model scales.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Annan teknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Other Engineering and Technologies (hsv//eng)
Nyckelord
- metro carriage fire; different scales; correlation; critical fire spread
- fire development
- local flashover
- maximum heat release rate
- Energy- and Environmental Engineering
- energi- och miljöteknik
Publikations- och innehållstyp
- vet (ämneskategori)
- rap (ämneskategori)
Hitta via bibliotek
Till lärosätets databas