SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:mdh-57623"
 

Sökning: onr:"swepub:oai:DiVA.org:mdh-57623" > Robust operation fo...

Robust operation for minimizing power consumption of data centers with flexible substation integration

Ji, H. (författare)
Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin, 300072, China
Chen, S. (författare)
Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin, 300072, China
Yu, H. (författare)
Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin, 300072, China
visa fler...
Li, P. (författare)
Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin, 300072, China
Yan, Jinyue, 1959- (författare)
Mälardalens universitet,Framtidens energi
Song, J. (författare)
Global Energy Interconnection Research Institute of State Grid, Beijing, 100000, China
Wang, C. (författare)
Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin, 300072, China
visa färre...
 (creator_code:org_t)
Elsevier Ltd, 2022
2022
Engelska.
Ingår i: Energy. - : Elsevier Ltd. - 0360-5442 .- 1873-6785. ; 248
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The rapid development of digital economy has led to a dramatic increasement of internet data centers (IDCs), which consume a large amount of electricity. The diverse data-processing demands, high power consumption and workload uncertainty put forward a high requirement for the economical and secure operation of IDCs. As information technology (IT) devices are driven by direct current (DC), flexible substation (FS) has been gradually utilized to provide DC power for IDCs. This paper proposes robust operation strategies for minimizing IDC power consumption with FS integration. First, the linearized IDC power consumption model based on the technology of dynamic voltage and frequency scaling (DVFS) is proposed to describe the operating state of IT devices. Then, considering the FS-based coordinated operation of IDC, photovoltaic (PV) station and energy storage system (ESS), the deterministic power consumption minimization model of IDCs is established. Considering the workload uncertainty, the operation strategies based on distributionally robust optimization (DRO) for IDCs are further proposed. Finally, the effectiveness of proposed method is validated on a modified practical network with IDCs integrated. Results show that through the dispatch of workload and power flow regulation of FS, the power consumption and dropping workload of IDCs are effectively reduced. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)

Nyckelord

Data centers
Distributionally robust optimization (DRO)
Flexible substation (FS)
Minimizing power consumption
Workload uncertainty

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Energy (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ji, H.
Chen, S.
Yu, H.
Li, P.
Yan, Jinyue, 195 ...
Song, J.
visa fler...
Wang, C.
visa färre...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
Artiklar i publikationen
Energy
Av lärosätet
Mälardalens universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy