SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:mdh-60082"
 

Sökning: onr:"swepub:oai:DiVA.org:mdh-60082" > Do ‘green’ data cen...

Do ‘green’ data centres really have zero CO2 emissions?

Wang, F. (författare)
Faculty of Maritime and Transportation, Ningbo University, Ningbo, 315211, China
Nian, V. (författare)
Centre for Strategic Energy and Resources, Singapore
Campana, Pietro Elia, 1984- (författare)
Mälardalens universitet,Framtidens energi
visa fler...
Jurasz, Jakob, PhD, 1990- (författare)
Mälardalens universitet,Framtidens energi,Wrocław University of Science and Technology, Wrocław, Poland
Li, Hailong, 1976- (författare)
Mälardalens universitet,Framtidens energi
Chen, L. (författare)
Key Laboratory of Thermo-Fluid Science and Engineering of MOE, School of Energy and Power Engineering, Xi'an Jiaotong University, Shaanxi, Xi'an, 710049, China
Tao, W. -Q (författare)
Key Laboratory of Thermo-Fluid Science and Engineering of MOE, School of Energy and Power Engineering, Xi'an Jiaotong University, Shaanxi, Xi'an, 710049, China
Yan, Jinyue, 1959- (författare)
Mälardalens universitet,Framtidens energi
visa färre...
 (creator_code:org_t)
Elsevier Ltd, 2022
2022
Engelska.
Ingår i: Sustainable Energy Technologies and Assessments. - : Elsevier Ltd. - 2213-1388 .- 2213-1396. ; 53
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The claim of a green data centre is generally made based on a net-zero CO2 emission through a ‘balance-sheet’ approach, which considers renewable electricity through on-site installation or purchase agreement as abatement measures against the use of fossil electricity from the electric grid on an annual basis. However, when the hourly dynamic fuel mix is accounted for in the assessment, the annual net-zero energy approach does not lead to a true carbon neutral data centre. In response, two approaches based on net-zero energy and net-zero CO2 emission respectively are proposed and investigated regarding the goal of net-zero CO2 emission. A data centre in Singapore with typical load profiles is used as a case study, different scenarios considering climate change and projected future energy are defined to examine the impacts of dynamic energy mix on the net CO2 emission of the data centre. The net-zero energy approach is found to result in significant amount of annual CO2 emissions. In comparison, the net-zero CO2 emission approach can assure a true net-zero CO2 emission, but this approach will require an increase of PV capacity by 20% and 60% as compared to the net-zero energy approach based on assessment for the year 2030 and 2050, respectively.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Dynamic energy mix
Green data centre
Hourly carbon intensity
Zero CO2 emission
Carbon
Climate change
Green computing
Balance sheet approach
Carbon intensity
CO 2 emission
Datacenter
Dynamic energy mixes
Energy approach
Green data centers
Renewable electricity
Carbon dioxide

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy