Sökning: onr:"swepub:oai:DiVA.org:miun-4477" >
Lung function and o...
-
Holmberg, Hans-ChristerMittuniversitetet,Institutionen för hälsovetenskap (-2013),Nationellt Vintersportcentrum / Swedish Winter Sports Research Centre,Mittuniversitetet, Institutionen för hälsovetenskap
(författare)
Lung function and oxygen uptake during double poling, running and diagonal skiing in elite cross-country skiers
- Artikel/kapitelEngelska2007
Förlag, utgivningsår, omfång ...
-
2006-10-13
-
Wiley,2007
-
printrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:miun-4477
-
https://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-4477URI
-
https://doi.org/10.1111/j.1600-0838.2006.00592.xDOI
-
https://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-84411URI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:art swepub-publicationtype
Anmärkningar
-
Arterial desaturation during exercise is common in endurance-trained athletes, a phenomenon often more pronounced when the muscle mass engaged in the exercise is large. With this background, the present study monitored seven international-level cross country skiers performing on a treadmill while running (RUN), double poling (DP; upper body exercise) and diagonal skiing (DIA; arm and leg exercise). Static and dynamic lung function tests were performed and oxygen uptake was measured during submaximal and maximal exercise. Lung function variables (including the diffusion capacity) were only 5-20% higher than reported in sedentary men. Vital capacity was considerably lower than expected from the skiers' maximal oxygen uptake (VO(2max)), but the maximal ventilation followed a linear relationship with VO(2max). None or only a mild desaturation was observed in DP, RUN and DIA. Blood lactate concentration was slightly higher in DIA than in DP but not different from RUN. In DIA, VO(2max) was 6.23 +/- 0.47 L/min (mean +/- SD), which was 3.8% and 13.9% higher than in RUN and DP, respectively, with similar peak heart rates for the three exercise modes. No relationships were present either between the degree of desaturation and pulmonary functions tests, or with peak oxygen uptakes. The low blood lactate accumulation during the exhaustive efforts contributed to the arterial oxygen saturation being mild in spite of the very high oxygen uptake observed in these skiers.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Rosdahl, Hans
(författare)
-
Svedenhag, Jan
(författare)
-
MittuniversitetetInstitutionen för hälsovetenskap (-2013)
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Scandinavian Journal of Medicine and Science in Sports: Wiley17:4, s. 437-4440905-71881600-0838
Internetlänk
Hitta via bibliotek