SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:oru-21715"
 

Sökning: onr:"swepub:oai:DiVA.org:oru-21715" > Calculation of righ...

Calculation of right ventricular stroke volume in short-axis MR images using the equation of the tricuspid plane

Jorstig, Stina Hellstrandh, 1978- (författare)
Örebro universitet,Institutionen för hälsovetenskap och medicin
Kähäri, Anders (författare)
Department of Radiology, Örebro University Hospital, Örebro, Sweden
Emilsson, Kent, 1963- (författare)
Department of Clinical Physiology, Örebro University Hospital, Örebro, Sweden
visa fler...
Thunberg, Per, 1968- (författare)
Department of Medical Physics, Örebro University Hospital, Örebro, Sweden
visa färre...
 (creator_code:org_t)
Malden, USA : Wiley-Blackwell, 2012
2012
Engelska.
Ingår i: Clinical Physiology and Functional Imaging. - Malden, USA : Wiley-Blackwell. - 1475-0961 .- 1475-097X. ; 32:1, s. 5-11
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Short-axis (SA) magnetic resonance (MR) images are commonly planned parallel to the left atrioventricular valve. This orientation leads to oblique slices of the right ventricle (RV) with subsequent difficulties in separating the RV from the right atrium in the SA images. The insertion points of the tricuspid valve (TV) in the myocardium can be clearly identified in the right ventricle long axis (RVLA) and four-chamber (4CH) views. The purpose of this study was to develop a method that transfers the position of the tricuspid plane, as seen in the RVLA and 4CH views, to the SA images to facilitate the separation of the RV from the atrium. This methodology, termed Dissociating the Right Atrium from the Ventricle Volume (DRAW), was applied in 20 patients for calculations of right ventricular stroke volume (RVSV). The RVSV using DRAW (RVSVDRAW) was compared to left ventricular stroke volumes (LVSV) obtained from flow measurements in the ascending aorta. The RVSV was also determined using the conventional method (RVSVCONV) where the stack of images from the SA views are summarized, and a visual decision is made of the most basal slice to be included in the RV. The mean difference between RVSVDRAW and LVSV was 0.1 +/- 12.7 ml, while the mean difference between RVSVCONV and LVSV was 0.33 +/- 14.3 ml. Both the intra- and interobserver variability were small using the DRAW methodology, 0.6 +/- 3.5 and 1.7 +/- 2.7 ml, respectively. In conclusion, the DRAW method can be used to facilitate the separation of the RV and the atrium.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Atrioventricular
cardiovascular magnetic resonance imaging
image analysis
right atrium
right ventricle
separating
tricuspid valve
ventricular function
Medicine
Medicin
Cardiology
Kardiologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jorstig, Stina H ...
Kähäri, Anders
Emilsson, Kent, ...
Thunberg, Per, 1 ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Örebro universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy