Sökning: onr:"swepub:oai:DiVA.org:oru-71655" >
Translating Glycate...
Translating Glycated Hemoglobin A1c into Time Spent in Glucose Target Range : a Multicenter Study
-
- Petersson, Jonathan (författare)
- School of Medical Sciences, Örebro University, Örebro, Sweden,Orebro Univ, Sweden
-
- Åkesson, Karin (författare)
- Linköpings universitet,Avdelningen för barns och kvinnors hälsa,Medicinska fakulteten,Ryhov Cty Hosp, Sweden
-
- Sundberg, Frida (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Institute of Clinical Sciences, Department of Pediatrics
-
visa fler...
-
- Särnblad, Stefan, 1963- (författare)
- Örebro universitet,Institutionen för medicinska vetenskaper,Department of Pediatrics, University Hospital Örebro, Örebro, Sweden,Orebro Univ, Sweden; Univ Hosp Orebro, Sweden
-
visa färre...
-
(creator_code:org_t)
- 2019-01-31
- 2019
- Engelska.
-
Ingår i: Pediatric Diabetes. - : Blackwell Publishing. - 1399-543X .- 1399-5448. ; 20:3, s. 339-344
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
https://gup.ub.gu.se...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: Approximately 90% of children and adolescents with type 1 diabetes in Sweden use continuous glucose monitoring (CGM), either as real-time CGM or intermittently scanned CGM to monitor their glucose levels. Time in target range (TIT) is an easily understandable metric for assessing glycemic control.Objective: The aim of this study was to examine the relation between TIT and hemoglobin A1c (HbA1c).Subjects and Methods: Subjects were recruited from three diabetes care centers in Sweden. Glucose data were collected for 133 children and adolescents with type 1 diabetes through CGM using Diasend. Subjects with registration time over 80% were included in the analysis. HbA1c was collected from SWEDIABKIDS, the Swedish pediatric diabetes quality registry. TIT was defined as 3.9 to 7.8 mmol/L (70-140 mg/dL) and time in range (TIR) as 3.9 to 10 mmol/L (70-180 mg/dL).Results: During the period of 60 days, 105 subjects provided complete data for analysis. Mean age was 12.2 (±3.3) years, mean HbA1c was 53.9 (±8.2) mmol/mol or 7.1% (±0.7%). Mean sensor glucose value was 8.6 (±1.3) mmol/L, mean coefficient of variation was 42.2% (±7.2%), mean TIT was 40.9% (±SD 12.2%), and mean TIR was 60.8% (±13.1%). There was a significant nonlinear relation between TIT during 60 days and HbA1c, R 2 = 0.69.Conclusion: This study suggests a nonlinear relation between time spent in glucose target range and HbA1c. The finding implies that time spent in TIT could be a useful metric in addition to HbA1c to assess glycemic control.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Pediatrik (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Pediatrics (hsv//eng)
Nyckelord
- HbA1c
- Type 1 diabetes
- children
- continuous glucose monitoring
- time in target range
Publikations- och innehållstyp