SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:oru-89692"
 

Sökning: onr:"swepub:oai:DiVA.org:oru-89692" > The no-touch saphen...

  • Dreifaldt, Mats,1959-Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Cardiothoracic and Vascular Surgery (författare)

The no-touch saphenous vein is an excellent alternative conduit to the radial artery 8 years after coronary artery bypass grafting : A randomized trial

  • Artikel/kapitelEngelska2021

Förlag, utgivningsår, omfång ...

  • Elsevier,2021
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:oru-89692
  • https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-89692URI
  • https://doi.org/10.1016/j.jtcvs.2019.09.177DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:145771623URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Funding Agencies:Nyckelfonden  Regional Research Committee, University Hospital, Örebro, Sweden  
  • Background: In 2004, a prospective randomized trial demonstrated that after 3 years, saphenous veins (SVs) harvested with a no touch (NT) technique had a greater patency than radial grafts for coronary bypass surgery. Here we report the 8-year follow-up data of this trial.Methods: The trial included 108 patients undergoing coronary artery bypass grafting (CABG). Each patient was assigned to receive 1 NT SV and 1 radial artery (RA) graft to either the left or right coronary territory to complement the left internal thoracic artery (LITA). Sequential grafting was common, so overall graft patency as well as the patency of each anastomosis were assessed.Results: Angiography was performed in 84 patients (78%) at mean of 97 months postoperatively. Graft patency were high and similar for both NT and RA: 86% for NT versus 79% for RA (P = .22). The patency of coronary anastomoses was significantly higher with the NT SV grafts (91% vs 81%; P = .046). The NT grafts also had excellent patency in coronary arteries with <90% stenosis (93% patency) and in coronary arteries of small diameter (87% patency) or with mild calcification (88% patency). Patency for the LITA was 92%.Conclusions: NT SV grafts have excellent patency similar to that of RA grafts after 8 years. In addition, NT SV grafts can be used in situations that are not ideal for RA grafts.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Mannion, John D.Department of Surgery, Bayhealth Medical Center, Dover, USA (författare)
  • Geijer, Håkan,1961-Örebro universitet,Institutionen för medicinska vetenskaper,Department of Radiology(Swepub:oru)hngr (författare)
  • Lidén, Mats,1976-Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Radiology(Swepub:oru)msld (författare)
  • Bodin, LennartKarolinska Institutet (författare)
  • de Souza, Domingos Ramos,1954-Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Cardiothoracic and Vascular Surgery(Swepub:oru)dra (författare)
  • Örebro universitetInstitutionen för medicinska vetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Thoracic and Cardiovascular Surgery: Elsevier161:2, s. 624-6300022-52231097-685X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy