Sökning: onr:"swepub:oai:DiVA.org:ri-49923" >
Heterogeneous 3D in...
Heterogeneous 3D integration of 17 μm pitch Si/SiGe quantum well bolometer arrays for infrared imaging systems
-
- Forsberg, Fredrik (författare)
- KTH,Mikro- och nanosystemteknik,KTH Royal Institute of Technology, Sweden
-
- Fischer, Andreas C., 1982- (författare)
- KTH,Mikro- och nanosystemteknik,KTH Royal Institute of Technology, Sweden
-
- Roxhed, Niclas (författare)
- KTH,Mikro- och nanosystemteknik,KTH Royal Institute of Technology, Sweden
-
visa fler...
-
- Samel, Björn (författare)
- RISE,Acreo,Acreo AB
-
- Ericsson, Per (författare)
- RISE,Acreo,Acreo AB
-
- Stemme, Göran (författare)
- KTH,Mikro- och nanosystemteknik,KTH Royal Institute of Technology, Sweden
-
- Niklaus, Frank (författare)
- KTH,Mikro- och nanosystemteknik,KTH Royal Institute of Technology, Sweden
-
visa färre...
-
(creator_code:org_t)
- 2013-03-06
- 2013
- Engelska.
-
Ingår i: Journal of Micromechanics and Microengineering. - : IOP Publishing. - 0960-1317 .- 1361-6439. ; 23:4
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- This paper reports on the realization of 17 μm × 17 μm pitch bolometer arrays for uncooled infrared imagers. Microbolometer arrays have been available in primarily defense applications since the mid-1980s and are typically based on deposited thin films on top of CMOS wafers that are surface-machined into sensor pixels. This paper instead focuses on the heterogeneous integration of monocrystalline Si/SiGe quantum-well-based thermistor material in a CMOS-compliant process using adhesive wafer bonding. The high-quality monocrystalline thermistor material opens up for potentially lower noise compared to commercially available uncooled microbolometer arrays together with a competitive temperature coefficient of resistance (TCR). Characterized bolometers had a TCR of -2.9% K-1 in vacuum, measured thermal conductances around 5 × 10-8 W K-1 and thermal time constants between 4.9 and 8.5 ms, depending on the design. Complications in the fabrication of stress-free bolometer legs and low-noise contacts are discussed and analyzed.
Nyckelord
- Adhesive wafer bonding
- Heterogeneous integration
- Microbolometer arrays
- Temperature coefficient of resistance
- Thermal conductance
- Thermal time constants
- Thermistor materials
- Uncooled microbolometers
- Infrared detectors
- Infrared imaging
- Semiconductor quantum wells
- Temperature sensors
- Thermistors
- Bolometers
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas