SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:ri-56688"
 

Sökning: onr:"swepub:oai:DiVA.org:ri-56688" > The short-term perf...

The short-term performances of two independent gas modulated refractometers for pressure assessments

Forssén, Clayton (författare)
Umeå universitet,RISE,Umeå University, Sweden,Institutionen för fysik,Measurement Science and Technology, RISE Research Institutes of Sweden, Borås, Sweden
Silander, Isak, 1980- (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
Zakrisson, Johan (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
visa fler...
Axner, Ove (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
Zelan, Martin (författare)
RISE,Mätteknik,Measurement Science and Technology, RISE Research Institutes of Sweden, Borås, Sweden
visa färre...
 (creator_code:org_t)
2021-09-18
2021
Engelska.
Ingår i: Sensors. - : MDPI. - 1424-8220. ; 21:18
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Refractometry is a powerful technique for pressure assessments that, due to the recent redefinition of the SI system, also offers a new route to realizing the SI unit of pressure, the Pascal. Gas modulation refractometry (GAMOR) is a methodology that has demonstrated an outstanding ability to mitigate the influences of drifts and fluctuations, leading to long-term precision in the 10−7 region. However, its short-term performance, which is of importance for a variety of applications, has not yet been scrutinized. To assess this, we investigated the short-term performance (in terms of precision) of two similar, but independent, dual Fabry–Perot cavity refractometers utilizing the GAMOR methodology. Both systems assessed the same pressure produced by a dead weight piston gauge. That way, their short-term responses were assessed without being compromised by any pressure fluctuations produced by the piston gauge or the gas delivery system. We found that the two refractometer systems have a significantly higher degree of concordance (in the 10−8 range at 1 s) than what either of them has with the piston gauge. This shows that the refractometry systems under scrutiny are capable of assessing rapidly varying pressures (with bandwidths up to 2 Hz) with precision in the 10−8 range. © 2021 by the authors.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Fabry–Perot cavity
Gas modulation
Metrology
Modulation techniques
Pressure
Refractometry
Short-term performance
Gages
Pistons
Dead weights
Gas delivery system
Piston gauges
Pressure fluctuation
Short term
Refractometers

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy