Sökning: onr:"swepub:oai:DiVA.org:ri-60151" >
Breathing air consu...
Breathing air consumption during different firefighting methods in underground mining environment
-
- Palm, Anders (författare)
- Mälardalens universitet,Framtidens energi,Greater Stockholm Fire Brigade, Malmskillnadsgatan 64, 113 83, Stockholm, Sweden; School of Business, Society and Engineering, Mälardalen University, PO Box 883, SE-721 23, Västerås, Sweden
-
- Kumm, Mia, 1967- (författare)
- Mälardalens universitet,RISE,Brand och Säkerhet,School of Business, Society and Engineering, Mälardalen University, PO Box 883, SE-721 23, Västerås, Sweden; Division of Safety and Transport, RISE Research Institutes of Sweden, PO Box 857, SE-501 15, Borås, Sweden,Framtidens energi
-
- Storm, Artur (författare)
- Luleå tekniska universitet,RISE,Brand och Säkerhet,Luleå University of Technology, Sweden,Division of Safety and Transport, RISE Research Institutes of Sweden, PO Box 857, Borås, SE-501 15, Sweden,Byggkonstruktion och brand
-
visa fler...
-
- Lönnermark, Anders, 1968- (författare)
- RISE,Brand och Säkerhet,Division of Safety and Transport, RISE Research Institutes of Sweden, PO Box 857, Borås, SE-501 15, Sweden
-
visa färre...
-
(creator_code:org_t)
- Elsevier Ltd, 2022
- 2022
- Engelska.
-
Ingår i: Fire safety journal. - : Elsevier Ltd. - 0379-7112 .- 1873-7226. ; 133
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- The paper analyses the breathing air consumption among participating firefighters during full-scale tests performed in the Tistbrottet mine in Sweden 2013. The availability of breathing air during firefighting has in earlier work been identified as a critical tactical factor in underground firefighting. Results from the tests show that there are differences in the breathing air consumption and that this depends on the methods used, equipment and the workload. The use of BA-teams, i.e. firefighters equipped with breathing apparatuses, is a complex group activity where the largest breathing air consumer will set the limits for the whole team. Light equipment and a structured command and control during the activities will enhance the endurance and the firefighting performance. Equipment and methods affect both firefighting performance and the durability of the firefighting activities. Examples of tested methods and equipment during the test series are: different variations of conventional hose lay-out; CAFS; cutting extinguisher; and trolley for equipment and complementary air. The aid of additional air supply and the use of trolleys will support the activities but is dependent on a large degree of preparation and training to function properly. Based on the tests, it is concluded that the larger model of air bottles should be considered for distances longer than 75 m. © 2022 The Authors
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Building Technologies (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Annan teknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Other Engineering and Technologies (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Annan samhällsbyggnadsteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Other Civil Engineering (hsv//eng)
Nyckelord
- BA-Operation
- Breathing air consumption
- Fire and rescue operation
- Fire in tunnels
- Underground firefighting
- Durability
- Fire extinguishers
- Air consumption
- Fire in tunnel
- Fire operations
- Mining environments
- Performance
- Rescue operations
- Underground mining
- Fires
- Byggkonstruktion
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas