Sampling of gaseous sulfur-containing compounds at low concentrations with a review of best-practice methods for biogas and natural gas applications
-
- Brown, Andrew S. (författare)
- NPL National Physical Laboratory, United Kingdom
-
- van der Veen, Adriaan M. H. (författare)
- VSL Dutch Metrology Institute, The Netherlands
-
- Arrhenius, Karine (författare)
- RISE,SP – Sveriges Tekniska Forskningsinstitut / Organisk kemi (Kmo)
-
visa fler...
-
- Murugan, Arul (författare)
- NPL National Physical Laboratory, United Kingdom
-
- Culleton, Lucy P. (författare)
- NPL National Physical Laboratory, United Kingdom
-
- Ziel, Paul R. (författare)
- VSL Dutch Metrology Institute, The Netherlands
-
- Li, Jianrong (författare)
- VSL Dutch Metrology Institute, The Netherlands
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2015
- 2015
- Engelska.
-
Ingår i: TrAC. Trends in analytical chemistry. - : Elsevier BV. - 0165-9936 .- 1879-3142. ; 64, s. 42-52
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The accurate quantification of low-concentration sulfur-containing compounds is essential for the biogas and natural gas industries. We review literature data for the stability of these compounds in standard gas mixtures when sampled in cylinders with different passivations, sample bags, sorbent tubes, solid-phase microextraction and glass sampling bulbs, and we present new data obtained at our three National Measurement Institutes. We show that losses of sulfur-containing compounds are minimized when using passivated sampling cylinders, and the most suitable sorbent material for sampling these compounds is Tenax TA. We also discuss methods for transferring gas from sample vessels to analyzers and give recommendations for the selection of regulators (and other pressure-reducing devices) and transfer lines. Further, we propose approaches that could be taken to reduce or correct for losses in order to provide more accurate measurements of sulfur-containing compounds.
Nyckelord
- Biogas
- Gas analysis
- Hydrogen sulfide
- Natural gas
- Passivated sampling cylinder
- Sampling
- Stability
- Standard gas mixture
- Sulfur-containing compound
- Trace level
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas