A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples
-
- Moein, Mohammad Mahdi (författare)
- Stockholms universitet,Institutionen för analytisk kemi
-
- Jabbar, Dunia (författare)
- Stockholms universitet,Institutionen för analytisk kemi
-
- Colmsjö, Anders (författare)
- Stockholms universitet,Institutionen för analytisk kemi
-
visa fler...
-
- Abdel-Rehim, Mohamed (författare)
- Stockholms universitet,Institutionen för analytisk kemi
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2014
- 2014
- Engelska.
-
Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673 .- 1873-3778. ; 1366, s. 15-23
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- In the present work, a needle trap utilizing a molecularly imprinted sal-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sal-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5 nmol L-1, respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000 nmol L-1 in both plasma and urine samples. The coefficients of determination values (R-2) were >= 0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples.
Ämnesord
- NATURVETENSKAP -- Kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences (hsv//eng)
- NATURVETENSKAP -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
- NATURAL SCIENCES -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)
Nyckelord
- Molecularly imprinted polymer
- Sol-gel
- Microextraction by packed sorbent
- Bilirubin
- Plasma
- Urine