SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:su-109808"
 

Sökning: onr:"swepub:oai:DiVA.org:su-109808" > A needle extraction...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003320naa a2200421 4500
001oai:DiVA.org:su-109808
003SwePub
008141201s2014 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-1098082 URI
024a https://doi.org/10.1016/j.chroma.2014.09.0122 DOI
040 a (SwePub)su
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Moein, Mohammad Mahdiu Stockholms universitet,Institutionen för analytisk kemi4 aut0 (Swepub:su)mmahd
2451 0a A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples
264 1b Elsevier BV,c 2014
338 a print2 rdacarrier
500 a AuthorCount:4;
520 a In the present work, a needle trap utilizing a molecularly imprinted sal-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sal-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5 nmol L-1, respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000 nmol L-1 in both plasma and urine samples. The coefficients of determination values (R-2) were >= 0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples.
650 7a NATURVETENSKAPx Kemi0 (SwePub)1042 hsv//swe
650 7a NATURAL SCIENCESx Chemical Sciences0 (SwePub)1042 hsv//eng
650 7a NATURVETENSKAPx Biologix Biokemi och molekylärbiologi0 (SwePub)106022 hsv//swe
650 7a NATURAL SCIENCESx Biological Sciencesx Biochemistry and Molecular Biology0 (SwePub)106022 hsv//eng
653 a Molecularly imprinted polymer
653 a Sol-gel
653 a Microextraction by packed sorbent
653 a Bilirubin
653 a Plasma
653 a Urine
700a Jabbar, Duniau Stockholms universitet,Institutionen för analytisk kemi4 aut
700a Colmsjö, Andersu Stockholms universitet,Institutionen för analytisk kemi4 aut0 (Swepub:su)colms
700a Abdel-Rehim, Mohamedu Stockholms universitet,Institutionen för analytisk kemi4 aut0 (Swepub:su)rabde
710a Stockholms universitetb Institutionen för analytisk kemi4 org
773t Journal of Chromatography Ad : Elsevier BVg 1366, s. 15-23q 1366<15-23x 0021-9673x 1873-3778
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-109808
8564 8u https://doi.org/10.1016/j.chroma.2014.09.012

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Moein, Mohammad ...
Jabbar, Dunia
Colmsjö, Anders
Abdel-Rehim, Moh ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
NATURVETENSKAP
NATURVETENSKAP
och Biologi
och Biokemi och mole ...
Artiklar i publikationen
Journal of Chrom ...
Av lärosätet
Stockholms universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy