SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:su-179516"
 

Sökning: onr:"swepub:oai:DiVA.org:su-179516" > Monte Carlo dosimet...

Monte Carlo dosimetry using Fluka code and experimental dosimetry with Gafchromic EBT2 and XR-RV3 of self-built experimental setup for radiobiological studies with low-energy X-rays

Czub, Joanna (författare)
Braziewicz, Janusz (författare)
Wasilewski, Adam (författare)
visa fler...
Wysocka-Rabin, Anna (författare)
Wołowiec, Paweł (författare)
Wójcik, Andrzej (författare)
Stockholms universitet,Institutionen för molekylär biovetenskap, Wenner-Grens institut,Jan Kochanowski University, Poland
visa färre...
 (creator_code:org_t)
2020-02-04
2020
Engelska.
Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 96:6, s. 718-733
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: The aim of this research was to simulate self-built experimental setup for radiobiological research using X-ray diffraction C-tech tube and PW 3830 generator (PANalytical, Netherlands) and to calculate absorbed dose and to compare it with experimental dose measurements. The maximum X-ray energy was 60 keV.Materials and methods: Petri dish was specially adapted to hold biological cells during the irradiation process. Rotation of Petri dish ensured radiation homogeneity and effectiveness of rotation process was confirmed using EBT2 Gafchromic film. Monte Carlo simulation using Fluka 2011 2c.4 was used to model the setup and to calculate dose absorbed by live cells. The EBT2 and XR-RV3 Gafchromic films were used to estimate relative experimental absorbed dose.Results: The radiation homogeneity provided values with maximum deviation equal to +/- 3.5% from the average value and the absorbed dose rate was 0.9 Gy/min using simulation process and 1 Gy/min or 0.8 Gy/min using experimental methods (XR-RV3 and EBT2 Gafchromic film, respectively). All dose rate values show metrological compatibility.Conclusions: Influence of specially constructed Petri dish on absorbed dose was determined using simulations that showed that low-energy photons, emitted as characteristic line from borosilicate glass forming component of Petri dish, were source of increase in dose absorbed by cells. This experimental setup will be used to conduct radiobiological research.

Ämnesord

NATURVETENSKAP  -- Biologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Monte Carlo simulation
low-energy X-ray
radiobiological research
Petri dish
EBT2 and XR-RV3 films

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy