Sökning: onr:"swepub:oai:DiVA.org:su-193684" > A UHV MOKE magnetom...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 02868naa a2200457 4500 | |
001 | oai:DiVA.org:su-193684 | |
003 | SwePub | |
008 | 210614s2021 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-1936842 URI |
024 | 7 | a https://doi.org/10.1107/S16005775210028852 DOI |
040 | a (SwePub)su | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Genuzio, Francesca4 aut |
245 | 1 0 | a A UHV MOKE magnetometer complementing XMCD-PEEM at the Elettra Synchrotron |
264 | 1 | c 2021 |
338 | a print2 rdacarrier | |
520 | a We report on a custom-built UHV-compatible Magneto-Optical Kerr Effect (MOKE) magnetometer for applications in surface and materials sciences, operating in tandem with the PhotoEmission Electron Microscope (PEEM) endstation at the Nanospectroscopy beamline of the Elettra synchrotron. The magnetometer features a liquid-nitrogen-cooled electromagnet that is fully compatible with UHV operation and produces magnetic fields up to about 140 mT at the sample. Longitudinal and polar MOKE measurement geometries are realized. The magneto-optical detection is based on polarization analysis using a photoelastic modulator. The sample manipulation system is fully compatible with that of the PEEM, making it possible to exchange samples with the beamline endstation, where complementary X-ray imaging and spectroscopy techniques are available. The magnetometer performance is illustrated by experiments on cobalt ultra-thin films, demonstrating close to monolayer sensitivity. The advantages of combining in situ growth, X-ray Magnetic Circular Dichroism imaging (XMCD-PEEM) and MOKE magnetometry into a versatile multitechnique facility are highlighted. | |
650 | 7 | a NATURVETENSKAPx Fysik0 (SwePub)1032 hsv//swe |
650 | 7 | a NATURAL SCIENCESx Physical Sciences0 (SwePub)1032 hsv//eng |
653 | a Magneto-Optical Kerr Effect | |
653 | a MOKE magnetometry | |
653 | a XMCD-PEEM | |
653 | a SPELEEM | |
653 | a in situ studies | |
700 | 1 | a Giela, Tomasz4 aut |
700 | 1 | a Lucian, Matteo4 aut |
700 | 1 | a Mentes, Tevfik Onur4 aut |
700 | 1 | a Brondin, Carlo Alberto4 aut |
700 | 1 | a Cautero, Giuseppe4 aut |
700 | 1 | a Mazalski, Piotr4 aut |
700 | 1 | a Bonetti, Stefanou Stockholms universitet,Fysikum,Ca’ Foscari University of Venice, Italy4 aut0 (Swepub:su)sbone |
700 | 1 | a Korecki, Jozef4 aut |
700 | 1 | a Locatelli, Andrea4 aut |
710 | 2 | a Stockholms universitetb Fysikum4 org |
773 | 0 | t Journal of Synchrotron Radiationg 28, s. 995-1005q 28<995-1005x 0909-0495x 1600-5775 |
856 | 4 | u https://doi.org/10.1107/S1600577521002885y Fulltext |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-193684 |
856 | 4 8 | u https://doi.org/10.1107/S1600577521002885 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy