SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:su-70659"
 

Sökning: onr:"swepub:oai:DiVA.org:su-70659" > Backscatter factors...

Backscatter factors and mass energy-absorption coefficient ratios for diagnostic radiology dosimetry

Benmakhlouf, Hamza (författare)
Stockholms universitet,Fysikum,Karolinska Institutet, Sweden
Bouchard, Hugo (författare)
Fransson, Annette (författare)
Karolinska Institutet
visa fler...
Andreo, Pedro (författare)
Stockholms universitet,Fysikum,Karolinska Institutet, Sweden
visa färre...
 (creator_code:org_t)
2011-10-25
2011
Engelska.
Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 56:22, s. 7179-7204
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Backscatter factors, B, and mass energy-absorption coefficient ratios, (mu(en)/rho)(omega,) (air), for the determination of the surface dose in diagnostic radiology were calculated using Monte Carlo simulations. The main purpose was to extend the range of available data to qualities used in modern x-ray techniques, particularly for interventional radiology. A comprehensive database for mono-energetic photons between 4 and 150 keV and different field sizes was created for a 15 cm thick water phantom. Backscattered spectra were calculated with the PENELOPE Monte Carlo system, scoring track-length fluence differential in energy with negligible statistical uncertainty; using the Monte Carlo computed spectra, B factors and (mu(en)/rho)(omega), air were then calculated numerically for each energy. Weighted averaging procedures were subsequently used to convolve incident clinical spectra with mono-energetic data. The method was benchmarked against full Monte Carlo calculations of incident clinical spectra obtaining differences within 0.3-0.6%. The technique used enables the calculation of B and (mu(en)/rho)(w), air for any incident spectrum without further time-consuming Monte Carlo simulations. The adequacy of the extended dosimetry data to a broader range of clinical qualities than those currently available, while keeping consistency with existing data, was confirmed through detailed comparisons. Mono-energetic and spectra-averaged values were compared with published data, including those in ICRU Report 74 and IAEA TRS-457, finding average differences of 0.6%. Results are provided in comprehensive tables appropriated for clinical use. Additional qualities can easily be calculated using a designed GUI interface in conjunction with software to generate incident photon spectra.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

Medical Radiation Physics
medicinsk strålningsfysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy