Thermal comfort, perceived air quality and cognitive performance when personally controlled air movement is used by tropically acclimatized persons

Schiavon, Stefano (författare)
Yang, Bin (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,School of Civil and Environmental Engineering, Nanyang Technological University, Singapore; Berkeley Education Alliance for Research in Singapore, Singapore,Building Energy Efficiency
Donner, Yoni (författare)
visa fler...
Chang, Wei-Chung (författare)
Nazaroff, William (författare)
visa färre...
 (creator_code:org_t)
2016-11-12
2017
Engelska.
Ingår i: Indoor Air. - : Hindawi Limited. - 0905-6947 .- 1600-0668. ; 27:3, s. 690-702
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In a warm and humid climate, increasing the temperature set point offers considerable energy benefits with low first costs. Elevated air movement generated by a personally controlled fan can compensate for the negative effects caused by an increased temperature set point. Fifty-six tropically acclimatized persons in common Singaporean office attire (0.7 clo) were exposed for 90 minutes to each of five conditions: 23, 26, and 29°C and in the latter two cases with and without occupant-controlled air movement. Relative humidity was maintained at 60%. We tested thermal comfort, perceived air quality, sick building syndrome symptoms, and cognitive performance. We found that thermal comfort, perceived air quality, and sick building syndrome symptoms are equal or better at 26°C and 29°C than at the common set point of 23°C if a personally controlled fan is available for use. The best cognitive performance (as indicated by task speed) was obtained at 26°C; at 29°C, the availability of an occupant-controlled fan partially mitigated the negative effect of the elevated temperature. The typical Singaporean indoor air temperature set point of 23°C yielded the lowest cognitive performance. An elevated set point in air-conditioned buildings augmented with personally controlled fans might yield benefits for reduced energy use and improved indoor environmental quality in tropical climates.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Schiavon, Stefan ...
Yang, Bin
Donner, Yoni
Chang, Wei-Chung
Nazaroff, Willia ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
Artiklar i publikationen
Indoor Air
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy