SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-154719"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-154719" > Test-re-test reliab...

  • Nyberg, AndreHeart and Lung Institute, University of Laval, Quebec, Canada (författare)

Test-re-test reliability of quadriceps muscle strength measures in people with more severe chronic obstructive pulmonary disease

  • Artikel/kapitelEngelska2018

Förlag, utgivningsår, omfång ...

  • Medical Journals Sweden AB,2018
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-154719
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-154719URI
  • https://doi.org/10.2340/16501977-2354DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • OBJECTIVE: To investigate the interday test-retest reliability of volitional and non-volitional measurements of isometric quadriceps strength using a strain-gauge in people with severe to very severe chronic obstructive pulmonary disease.DESIGN: Cross-sectional study. Volitional quadriceps measurements consisted of isometric maximal voluntary contractions. Non-volitional measurements were obtained during magnetic potentiated twitch stimulations of the femoral nerve.SETTING: Research centre laboratory.PARTICIPANTS: Twenty-four individuals with severe to very severe chronic obstructive pulmonary disease (percentage of predicted forced expiratory volume in 1 s, 37% predicted).RESULTS: Maximal voluntary contractions and potentiated twitch stimulations measures demonstrated excellent interday test-retest relative reliability (ICC 0.97 and 0.80, respectively), while absolute reliability measures were different between techniques (SEM 1.4 kg, CV 3.2%, MDC 3.9 kg vs SEM 1.5 kg, CV 12.2%, MDC 4.2 kg for maximal voluntary contractions and potentiated twitch stimulations, respectively).CONCLUSION: The results supports that maximal voluntary contraction and potentiated twitch stimulation measurements of isometric quadriceps strength are reliable in people with severe to very severe chronic obstructive pulmonary disease as evident excellent relative reliability using both techniques, although the former technique appears to have better absolute reliability.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Saey, Didier (författare)
  • Martin, Mickaël (författare)
  • Maltais, François (författare)
  • Heart and Lung Institute, University of Laval, Quebec, Canada (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Rehabilitation Medicine: Medical Journals Sweden AB50:8, s. 759-7641650-19771651-2081

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Nyberg, Andre
Saey, Didier
Martin, Mickaël
Maltais, Françoi ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Sjukgymnastik
Artiklar i publikationen
Journal of Rehab ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy