SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-168171"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-168171" > Accuracy and Reliab...

Accuracy and Reliability of Smartphone Self-Test Audiometry in Community Clinics in Low Income Settings : A Comparative Study

Sandström, Josefin (författare)
Umeå universitet,Allmänmedicin
Swanepoel, DeWet (författare)
Laurent, Claude (författare)
Umeå universitet,Öron- näs- och halssjukdomar,Department of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, South Africa
visa fler...
Umefjord, Göran (författare)
Umeå universitet,Allmänmedicin
Lundberg, Thorbjörn (författare)
Umeå universitet,Allmänmedicin
visa färre...
 (creator_code:org_t)
2020-01-22
2020
Engelska.
Ingår i: Annals of Otology, Rhinology and Laryngology. - : Sage Publications. - 0003-4894 .- 1943-572X. ; 129:6, s. 578-584
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: There is a lack of hearing health care globally, and tele-audiology and mobile technologies have been proposed as important strategies to reduce the shortfall. Objectives: To investigate the accuracy and reliability of smartphone self-test audiometry in adults, in community clinics in low-income settings.Methods: A prospective, intra-individual, repeated measurements design was used. Sixty-three adult participants (mean age 52 years, range 20-88 years) were recruited from ENT and primary health care clinics in a low-income community in Tshwane, South Africa. Air conduction hearing thresholds for octave frequencies 0.5 to 8 kHz collected with the smartphone self-test in non-sound treated environments were compared to those obtained by reference audiometry.Results: The overall mean difference between threshold seeking methods (ie, smartphone thresholds subtracted from reference) was -2.2 dB HL (n = 467 thresholds, P = 0.00). Agreement was within 10 dB HL for 80.1% (n = 467 thresholds) of all threshold comparisons. Sensitivity for detection hearing loss >40 dB HL in one ear was 90.6% (n = 84 ears), and specificity 94.2% (n = 84 ears).Conclusion: Smartphone self-test audiometry can provide accurate and reliable air conduction hearing thresholds for adults in community clinics in low-income settings.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oto-rhino-laryngologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Otorhinolaryngology (hsv//eng)

Nyckelord

audiometry
global health
hearing loss
mHealth
smartphone
telemedicine

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy