Diagnosis of left ventricular hypertrophy using non-ECG-gated 15O-water PET
-
- Sörensen, Jens (författare)
- Uppsala universitet,Radiologi
-
- Nordström, Jonny (författare)
- Uppsala universitet,Radiologi
-
- Baron, Tomasz (författare)
- Uppsala universitet,Institutionen för medicinska vetenskaper,Uppsala kliniska forskningscentrum (UCR)
-
visa fler...
-
- Mörner, Stellan (författare)
- Umeå universitet,Avdelningen för medicin
-
- Granstam, Sven-Olof, 1963- (författare)
- Uppsala universitet,Klinisk fysiologi
-
- Lubberink, Mark (författare)
- Uppsala universitet,Radiologi
-
- Tolbod, Lars (författare)
- Nuclear Medicine and PET, Institute of Clinical Medicine, Aarhus University, Aarhus, Denmark
-
- van den Berg, Jeffrey (författare)
- Uppsala universitet,Institutionen för kirurgiska vetenskaper
-
- Flachskampf, Frank A. (författare)
- Uppsala universitet,Institutionen för medicinska vetenskaper
-
- Kero, Tanja (författare)
- Uppsala universitet,Radiologi
-
- Magnusson, Peter (författare)
- Karolinska Institutet
-
- Harms, Hendrik J (författare)
- Uppsala universitet,Radiologi
-
visa färre...
-
(creator_code:org_t)
- 2021-07-20
- 2022
- Engelska.
-
Ingår i: Journal of Nuclear Cardiology. - : Springer. - 1071-3581 .- 1532-6551. ; , s. 2361-2373
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://umu.diva-por... (primary) (Raw object)
-
https://link.springe...
-
https://uu.diva-port... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- Aim: To develop a method for diagnosing left ventricular (LV) hypertrophy from cardiac perfusion 15O-water positron emission tomography (PET).Methods: We retrospectively pooled data from 139 subjects in four research cohorts. LV remodeling patterns ranged from normal to severe eccentric and concentric hypertrophy. 15O-water PET scans (n = 197) were performed with three different PET devices. A low-end scanner (66 scans) was used for method development, and remaining scans with newer devices for a blinded evaluation. Dynamic data were converted into parametric images of perfusable tissue fraction for semi-automatic delineation of the LV wall and calculation of LV mass (LVM) and septal wall thickness (WT). LVM and WT from PET were compared to cardiac magnetic resonance (CMR, n = 47) and WT to 2D-echocardiography (2DE, n = 36). PET accuracy was tested using linear regression, Bland–Altman plots, and ROC curves. Observer reproducibility were evaluated using intraclass correlation coefficients.Results: High correlations were found in the blinded analyses (r ≥ 0.87, P < 0.0001 for all). AUC for detecting increased LVM and WT (> 12 mm and > 15 mm) was ≥ 0.95 (P < 0.0001 for all). Reproducibility was excellent (ICC ≥ 0.93, P < 0.0001).Conclusion: 15O-water PET might detect LV hypertrophy with high accuracy and precision.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- 15O-water
- Cardiac remodeling
- Left ventricular hypertrophy
- Positron emission tomography
- Wall thickness
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Sörensen, Jens
-
Nordström, Jonny
-
Baron, Tomasz
-
Mörner, Stellan
-
Granstam, Sven-O ...
-
Lubberink, Mark
-
visa fler...
-
Tolbod, Lars
-
van den Berg, Je ...
-
Flachskampf, Fra ...
-
Kero, Tanja
-
Magnusson, Peter
-
Harms, Hendrik J
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
Journal of Nucle ...
- Av lärosätet
-
Umeå universitet
-
Uppsala universitet
-
Karolinska Institutet