SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-40234"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-40234" > Chromium-51-EDTA cl...

Chromium-51-EDTA clearance in adults with a single-plasma sample

Mårtensson, Johan (författare)
Groth, Steffen (författare)
Umeå universitet,Klinisk fysiologi
Rehling, Michael (författare)
visa fler...
Gref, Margareta, 1950- (författare)
Umeå universitet,Klinisk fysiologi
visa färre...
 (creator_code:org_t)
1998
1998
Engelska.
Ingår i: Journal of Nuclear Medicine. - 0161-5505 .- 1535-5667. ; 39:12, s. 2131-2137
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In 1996, a committee on renal clearance recommended a mean sojourn time-based methodology for single-sample determination of plasma clearance of 99mTc-diethylenetriamine pentaacetic acid (DTPA) to be used on adults if the patient's glomerular filtration rate (GFR) is suspected to be >30 ml/min. The main purpose of this study was to derive a mean sojourn time-based formula for calculation of 51Cr-ethylenediamine tetraacetic acid (EDTA) clearance in adults. Methods: Two groups of patients with 51Cr-EDTA clearance (CI) between 16 and 172 ml/min were studied. In Group I (n = 46), reference CI was determined as a multi plasma sample, single-injection method (CISM). Sixteen blood samples were drawn from 0 until 5 hr after a single intravenous injection of 51Cr-EDTA. In Group II (n = 1046), reference CI was determined by the Brøchner-Mortensen four-sample clearance method (CIBM). The plasma timeactivity curves of Group I were used to derive two mean sojourn time-based formulas (Formulas 1 and 2) for calculation of a single sample clearance. Formula 1 was derived from the entire time activity curve, whereas the derivation of Formula 2 used only the final slope of the time-activity curve. The accuracy of the two formulas and the Christensen and Groth 99mTc-DTPA formula was tested on Group II. Results: Chromium-51-EDTA CI calculated by Formula 1 was almost identical to the CI calculated by the reference CI method (r = 0.982; SDdiff = 5.82 ml/min). Both 51Cr-EDTA CI calculated by Formula 2 and by the 99mTc-DTPA formula showed close correlation with the reference method (r = 0.976, r = 0.985, respectively) but systematically overestimated GFR for the whole range of clearance values by 3.5 and 3.2 ml/min (p < 0.001), respectively. Conclusion: It is possible to get an accurate determi nation of 51Cr-EDTA CI from a single-plasma sample in adults by the mean sojourn time methodology. The determination is marginally more accurate (p < 0.001) if using a formula derived from the entire plasma time-activity curve than from only the final slope. The single-sample formula derived for determination of 99mTc-DTPA CI tends slightly to overestimate GFR if used to calculate 51Cr-EDTA CI.

Nyckelord

single sample
chromium-51-ethylenediaminetetraacetic acid clearance
glomerular filtration rate
renal function

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy