A virtual reality test battery for assessment and screening of spatial neglect
- Artikel/kapitelEngelska2011
Förlag, utgivningsår, omfång ...
-
2011-01-27
-
John Wiley & Sons,2011
-
printrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:umu-51122
-
https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-51122URI
-
https://doi.org/10.1111/j.1600-0404.2010.01390.xDOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:art swepub-publicationtype
Anmärkningar
-
Background – There is a need for improved screening methods for spatial neglect.Aim – To construct a VR-test battery and evaluate its accuracy and usability in patients with acute stroke.Method – VR-DiSTRO consists of a standard desktop computer, a CRT monitor and eye shutter stereoscopic glasses, a force feedback interface, and software, developed to create an interactive and immersive 3D experience. VR-tests were developed and validated to the conventional Star Cancellation test, Line bisection, Baking Tray Task (BTT), and Visual Extinction test. A construct validation to The Rivermead Behavioral Inattention Test, used as criterion of visuospatial neglect, was made. Usability was assessed according to ISO 9241-11.Results – Thirty-one patients with stroke were included, 9/31 patients had neglect. The sensitivity was 100% and the specificity 82% for the VR-DiSTRO to correctly identify neglect. VR-BTT and VR-Extinction had the highest correlation (r2 = 0.64 and 0.78), as well as high sensitivity and specificity. The kappa values describing the agreement between traditional neglect tests and the corresponding virtual reality test were between 0.47–0.85. Usability was assessed by a questionnaire; 77% reported that the VR-DiSTRO was ‘easy’ to use. Eighty-eight percent reported that they felt ‘focused’, ‘pleased’ or ‘alert’. No patient had adverse symptoms. The test session took 15 min.Conclusions – The VR-DiSTRO quickly and with a high accuracy identified visuospatial neglect in patients with stroke in this construct validation. The usability among elderly patients with stroke was high. This VR-test battery has the potential to become an important screening instrument for neglect and a valuable adjunct to the neuropsychological assessment.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Bodin, KennethUmeå universitet,Högpresterande beräkningscentrum norr (HPC2N),UMIT(Swepub:umu)kebo0001
(författare)
-
Bucht, GustafUmeå universitet,Geriatrik(Swepub:umu)gubu0001
(författare)
-
Malm, JanUmeå universitet,Klinisk neurovetenskap(Swepub:umu)jama0002
(författare)
-
Umeå universitetKlinisk neurovetenskap
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Acta Neurologica Scandinavica: John Wiley & Sons123:3, s. 167-1740001-63141600-0404
Internetlänk
Hitta via bibliotek
Till lärosätets databas