SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-66530"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-66530" > On-line computerize...

On-line computerized vectorcardiography monitoring of myocardial ischemia during coronary angioplasty : comparison with 12-lead electrocardiography

Jensen, Steen (författare)
Umeå universitet,Kardiologi
Johansson, Göran (författare)
Umeå universitet,Anestesiologi och intensivvård
Osterman, Göran (författare)
visa fler...
Reiz, Sebastian (författare)
Umeå universitet,Anestesiologi och intensivvård
Näslund, Ulf (författare)
Umeå universitet,Kardiologi
visa färre...
 (creator_code:org_t)
1994
1994
Engelska.
Ingår i: Coron Artery Dis. ; 5:6, s. 507-14
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: With new interventions minimizing ischemic myocardial injury, accurate and reliable techniques for the detection and continuous monitoring of myocardial ischemia are essential. We compared two techniques used for the detection of myocardial ischemia during coronary angioplasty: on-line computerized vectorcardiographic (cVCG) monitoring and the standard electrocardiography (ECG) leads or the complete 12-lead ECG. METHODS: Thirty patients scheduled for routine angioplasty were included in the study. cVCG was recorded continuously. The electrodes were placed according to the lead system described by Frank and connected to a computerized system for on-line vectorcardiography. A 12-lead ECG was recorded simultaneously. The absolute variable spatial ST vector magnitude (ST-VM) and the relative variable spatial ST change vector magnitude (STC-VM) were calculated and compared with the standard 12-lead ECG for the detection of ischemia. RESULTS: The sum of deviation in ST segment in all 12 standard ECG leads correlated closely with STC-VM, irrespective of which artery was occluded. STC-VM indicated ischemia during the first balloon inflation in 87% of the patients and demonstrated ischemia in more patients than the standard 12-lead ECG. Myocardial ischemia was not demonstrated by ST-VM in five out of 26 patients with ischemia according to STC-VM. In these cases, mainly directional vector changes and fewer changes in magnitude were observed. CONCLUSION: Compared with 12-lead ECG, on-line cVCG is a more sensitive method of detecting myocardial ischemia during coronary angioplasty and the reading is easier and faster. Our results support STC-VM > or = 0.050 mV as the criterion for ischemia during angioplasty; ST-VM should be applied together with STC-VM.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Angina Pectoris/etiology
*Angioplasty
Transluminal
Percutaneous Coronary/adverse effects
*Computer Systems
Coronary Vessels
Electrocardiography/instrumentation/*methods
Female
Humans
Male
Middle Aged
Monitoring
Physiologic/instrumentation
Myocardial Ischemia/*diagnosis/etiology
*Online Systems
Sensitivity and Specificity
*Vectorcardiography/instrumentation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jensen, Steen
Johansson, Göran
Osterman, Göran
Reiz, Sebastian
Näslund, Ulf
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy