SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-73723"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-73723" > Blood flow of ophth...

  • Ambarki, KhalidUmeå universitet,Radiofysik (författare)

Blood flow of ophthalmic artery in healthy individuals determined by phase-contrast magnetic resonance imaging

  • Artikel/kapitelEngelska2013

Förlag, utgivningsår, omfång ...

  • Association for Research in Vision and Ophthalmology (ARVO),2013
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-73723
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-73723URI
  • https://doi.org/10.1167/iovs.13-11737DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • PURPOSE: Recent development of magnetic resonance imaging (MRI) offers new possibilities to assess ocular blood flow. This prospective study evaluates the feasibility of phase-contrast MRI (PCMRI) to measure flow rate in the ophthalmic artery (OA) and establish reference values in healthy young (HY) and elderly (HE) subjects.METHODS: Fifty HY subjects (28 females, 21-30 years of age) and 44 HE (23 females, 64-80 years of age) were scanned on a 3-Tesla MR system. The PCMRI sequence had a spatial resolution of 0.35 mm per pixel, with the measurement plan placed perpendicularly to the OA. Mean flow rate (Qmean), resistive index (RI), and arterial volume pulsatility of OA (ΔVmax) were measured from the flow rate curve. Accuracy of PCMRI measures was investigated using a vessel-phantom mimicking the diameter and the flow rate range of the human OA.RESULTS: Flow rate could be assessed in 97% of the OAs. Phantom investigations showed good agreement between the reference and PCMRI measurements with an error of <7%. No statistical difference was found in Qmean between HY and HE individuals (HY: mean ± SD = 10.37 ± 4.45 mL/min; HE: 10.81 ± 5.15 mL/min, P = 0.655). The mean of ΔVmax (HY: 18.70 ± 7.24 μL; HE: 26.27 ± 12.59 μL, P < 0.001) and RI (HY: 0.62 ± 0.08; HE: 0.67 ± 0.1, P = 0.012) were significantly different between HY and HE.CONCLUSIONS: This study demonstrated that the flow rate of OA can be quantified using PCMRI. There was an age difference in the pulsatility parameters; however, the mean flow rate appeared independent of age. The primary difference in flow curves between HE and HY was in the relaxation phase of the systolic peak.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Hallberg, PerUmeå universitet,Radiofysik(Swepub:umu)perhag97 (författare)
  • Jóhannesson, GautiUmeå universitet,Oftalmiatrik(Swepub:umu)gaijon02 (författare)
  • Lindén, ChristinaUmeå universitet,Oftalmiatrik(Swepub:umu)chli0002 (författare)
  • Zarrinkoob, LalehUmeå universitet,Klinisk neurovetenskap(Swepub:umu)laza0003 (författare)
  • Wåhlin, AndersUmeå universitet,Radiofysik,Umeå centrum för funktionell hjärnavbildning (UFBI)(Swepub:umu)arswan02 (författare)
  • Birgander, RichardUmeå universitet,Diagnostisk radiologi(Swepub:umu)ribi0006 (författare)
  • Malm, JanUmeå universitet,Klinisk neurovetenskap(Swepub:umu)jama0002 (författare)
  • Eklund, AndersUmeå universitet,Klinisk neurovetenskap(Swepub:umu)anek0025 (författare)
  • Umeå universitetRadiofysik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Investigative Ophthalmology and Visual Science: Association for Research in Vision and Ophthalmology (ARVO)54:4, s. 2738-27450146-04041552-5783

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy