SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-9582"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-9582" > Perfluorosulfonated...

  • Appelblad, PatrikUmeå universitet,Kemiska institutionen,Institutionen för klinisk vetenskap (författare)

Perfluorosulfonated Ionomer-Modified Polyethylene. A Material for Simultaneous Solid-Phase Enrichment and Enhanced Precolumn Dansylation of C-21 Ketosteroids in Human Serum

  • Artikel/kapitelEngelska2001

Förlag, utgivningsår, omfång ...

  • 2001-06-30
  • American Chemical Society (ACS),2001
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-9582
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-9582URI
  • https://doi.org/10.1021/ac010071wDOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • A new derivatization procedure has been developed where solid-phase catalysis is utilized to facilitate the formation of hydrazones in precolumn labeling of keto-containing compounds. This procedure has been implemented on a solid-phase enrichment and enhanced derivatization (SPEED) device, prepared from porous polyethylene that has been coated with Nafion and dansylhydrazine. The SPEED devices have been optimized using experimental design and characterized for dansylation of C-21 ketosteroids by multivariate data analysis, using progesterone as the model compound. The reaction temperature and the molar ratio between the steroid and the derivatization reagent were found to be the factors most strongly affecting the reaction. Faster reaction kinetics were achieved when the molar ratio between dansylhydrazine and the steroid was increased. Mass spectroscopic analysis showed that the four derivative peaks eluting when derivatized progesterone was separated on an octadecyl silica stationary phase were due to the syn and anti mono- and bis(hydrazones) formed in the reaction. Using optimal reaction conditions, the derivatives mainly constitute the syn and anti conformers of bis-derivatives. In contrast to solution-based acid catalysis, the SPEED device was remarkably insensitive to water in the reaction mixture. A sample volume of 400 L was found to be the maximum, enabling sample enrichment prior derivatization. Using optimal experimental conditions, picomole amounts of ketosteroids could be derivatized in 10 min at room temperature. Analysis of spiked serum samples containing 0.4-2.0 nmol of progesterone showed overall recoveries of 52-63%. The corresponding 3 detection limit was 1.3 pmol (n = 4, 100 L injected), as estimated from calibration curve data.

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Ahmed, AbduUmeå universitet,Kemiska institutionen (författare)
  • Pontén, EinarUmeå universitet,Kemiska institutionen (författare)
  • Bäckström, TorbjörnUmeå universitet,Institutionen för klinisk vetenskap(Swepub:umu)toba0001 (författare)
  • Irgum, KnutUmeå universitet,Kemiska institutionen(Swepub:umu)knir0001 (författare)
  • Umeå universitetKemiska institutionen (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Analytical Chemistry: American Chemical Society (ACS)73:15, s. 3701-80003-27001520-6882

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy