SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-136591"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-136591" > A method to separat...

A method to separate the rectum from the prostate during proton beam radiotherapy of prostate cancer patients

Isacsson, Ulf (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
Nilsson, Kristina (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
Asplund, Stefan (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
visa fler...
Morhed, Elizabeth (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
Montelius, Anders (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
Turesson, Ingela (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
visa färre...
 (creator_code:org_t)
2010-04-16
2010
Engelska.
Ingår i: Acta Oncologica. - : Informa UK Limited. - 0284-186X .- 1651-226X. ; 49:4, s. 500-505
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The use of protons for curative treatment of prostate cancer is increasing, either as a single treatment modality or in combination with conventional radiotherapy. The proximity between prostate (target) and rectum (organ at risk) often leads to a compromise between dose to target and organ at risk. Material and methods. The present study describes a method where the distance between prostate and rectum is increased by retraction of the rectum in dorsal direction. Comparative treatment plans with and without retraction of the rectum in the same patients have been studied. Nine patients with biopsy proven, localised adenocarcinoma of the prostate were studied. A cylindrical rod of Perspex was inserted into the rectum. This device allows the rectum to be retracted posteriorly. The patients were given a proton boost of 20 Gy in four fractions of 5 Gy in addition to a conventional photon beam treatment to a dose of 50 Gy in 25 fractions of 2 Gy. Results. Comparative treatment planning shows that the treatment plan with rectal retraction significantly reduces (p < 0.01) the volume of the rectal wall receiving high doses (equal to 70 Gy in 2 Gy fractions) in all patients. Conclusions. The proton boost treatment with retraction of rectum during treatment decreases the rectal dose substantially. This is expected to reduce rectal side effects.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy