Sökning: onr:"swepub:oai:DiVA.org:uu-151901" >
Multicenter analyti...
Multicenter analytical evaluation of a high-sensitivity troponin T assay
-
Saenger, A. K. (författare)
-
Beyrau, R. (författare)
-
Braun, S. (författare)
-
visa fler...
-
- Cooray, Ruby (författare)
- Uppsala universitet,Institutionen för medicinska vetenskaper
-
Dolci, A. (författare)
-
Freidank, H. (författare)
-
Giannitsis, E. (författare)
-
Gustafson, S. (författare)
-
Handy, B. (författare)
-
Katus, H. (författare)
-
Melanson, S. E. (författare)
-
Panteghini, M. (författare)
-
- Venge, Per (författare)
- Uppsala universitet,Institutionen för medicinska vetenskaper
-
Zorn, M. (författare)
-
Jarolim, P. (författare)
-
Bruton, D. (författare)
-
Jarausch, J. (författare)
-
Jaffe, A. S. (författare)
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2011
- 2011
- Engelska.
-
Ingår i: Clinica Chimica Acta. - : Elsevier BV. - 0009-8981 .- 1873-3492. ; 412:9-10, s. 748-754
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: High-sensitivity cardiac troponin assays are being introduced clinically for earlier diagnosis of acute myocardial infarction (AMI). We evaluated the analytical performance of a high-sensitivity cardiac troponin T assay (hscTnT. Roche Diagnostics) in a multicenter, international trial. Methods: Three US and 5 European sites evaluated hscTnT on the Modular (R) Analytics E170, cobas (R) 6000, Elecsys 2010, and cobas (R) e 411. Precision, accuracy, reportable range, an inter-laboratory comparison trial, and the 99th percentile of a reference population were assessed. Results: Total imprecision (CVs) were 4.6-36.8% between 3.4 and 10.3 ng/L hscTnT. Assay linearity was up to 10,000 ng/L and the limit of blank and detection were 3 and 5 ng/L, respectively. The 99th percentile reference limit was 14.2 ng/L (n = 533). No significant differences between specimen types, assay incubation time, or reagent lots existed. A substantial positive bias (76%) exists between the 4th generation and hscTnT assays at the low end of the measuring range (< 50 ng/L). hscTnT serum pool concentrations were within 2SD limits of the mean of means in the comparison trial, indicating comparable results across multiple platforms and laboratories. Conclusion: The Roche hscTnT assay conforms to guideline precision requirements and will likely identify additional patients with myocardial injury suspicious for AMI.
Nyckelord
- Troponin
- 99th percentile
- High-sensitivity
- Acute myocardial infarction
- Cardiac biomarkers
- MEDICINE
- MEDICIN
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Saenger, A. K.
-
Beyrau, R.
-
Braun, S.
-
Cooray, Ruby
-
Dolci, A.
-
Freidank, H.
-
visa fler...
-
Giannitsis, E.
-
Gustafson, S.
-
Handy, B.
-
Katus, H.
-
Melanson, S. E.
-
Panteghini, M.
-
Venge, Per
-
Zorn, M.
-
Jarolim, P.
-
Bruton, D.
-
Jarausch, J.
-
Jaffe, A. S.
-
visa färre...
- Artiklar i publikationen
-
Clinica Chimica ...
- Av lärosätet
-
Uppsala universitet